TemperatureWise for walk-in coolers and freezers

Walk-in cooler and freezer temperature monitoring system

Know a walk-in is failing before the stock is at risk. TemperatureWise is a walk-in cooler and freezer temperature monitoring system: a wireless sensor at product height in each walk-in, a reading every 15 minutes, and alerts that learn each box's own pattern, so the rush and the defrosts are not alarms. Two walk-ins cost $1,050 up front and $1,000 a year.

  • Walk-in coolers
  • Walk-in freezers
  • Restaurants and kitchens
  • Stores and cold rooms
Inside a loaded walk-in cooler: wire shelving with food containers, a sheet pan rack, and the evaporator fans above. A TemperatureWise sensor is clipped to a shelving upright, marked with a red box, and shown close up on the right.
$1,050up front for two walk-ins, then $1,000 a year
$1,050 up frontand $1,000 a year, for two walk-insTemperatureWise price list
39 of 46 daysa 41°F alarm would have gone off on one busy walk-in, almost always from the doorWalk-in cooler troubleshooting, 2026
53 hoursof warning before a walk-in freezer's failed defrost timer peakedPhiladelphia, April 2025
An animated drawing of how TemperatureWise readings travel. Inside the cold box, a sensor clipped to a shelf takes a reading and sends it by radio through the wall, with nothing drilled, to the gateway on site. The gateway passes it over the internet or cellular to the Renergy cloud, where AI watches every reading, and the cloud puts it in the app as a new point on the chart. Green readings travel one after another. Then one reading comes in too warm and turns red: the cloud flags it, the app plots it above the line, and an alert goes to a phone, first as an email, then a text, then a phone call, until someone answers.

What you get

Four things TemperatureWise does as a walk-in temperature monitoring system

The TemperatureWise app showing a portfolio with a receiving dock, a blast cell and a freezer hall, each with its latest reading.Illustrative data

Your walk-ins, on your phone

See every walk-in cooler and freezer from anywhere, with the latest reading and the trend. Each alert names the box.

The four links between a freezer sensor and your phone. The sensor runs on its own battery and keeps reading in a power cut. The gateway and your internet run on mains and go down. The cloud and the mobile network keep running, so the alert is raised there.

A power cut on a closed day still reaches you

The sensors run on their own batteries. If a power cut takes down the gateway or your internet, the TemperatureWise cloud notices the silence and alerts you.

What happens when the power goes out
The TemperatureWise app showing a temperature trend chart for one unit over a 24 hour period.Illustrative data

The log fills itself in

Every reading is kept, so the record covers the nights and the days you were closed, not only the times somebody wrote a number down.

TemperatureWise alert settings with three steps: email, then a text message, then a phone call, each after a delay.Illustrative data

Alerts climb until someone answers

Email, then a text, then a call, to up to three people for each sensor. A Sunday fault reaches the manager, then the owner.

Where it goes wrong

Three walk-in failures worth an alert, and the daily ups and downs that aren't

A walk-in's temperature moves every time the door opens. The job is to tell a busy day from the start of a failure, and to wake someone only for the second.

A line chart of a walk-in cooler in a busy coffee shop, from noon on 30 March to noon on 2 April 2026. On the night of 30 March it sits near 35°F (2°C) with a small ripple. At midday on 31 March long door openings push it to 54°F (12.5°C). For the next 23 hours it does not get back below 38°F (3.4°C), and overnight it sits almost flat near 39°F (4°C), under the dashed 41°F alarm line, with no ripple. At about 11 AM on 1 April it drops back to normal.
From the data

The whole night, in a busy coffee shop's walk-in, March 2026

A walk-in that stops cycling and sits just under the line

In a busy coffee shop's walk-in, long door openings at midday pushed the air to 54°F (12.5°C), and it did not come back. For 23 hours it never got below 38°F (3.4°C). Overnight it sat almost flat near 39°F (4°C), with no ripple. A 41°F (5°C) alarm stayed quiet, because 39°F is under the line.

How fast
Hours
What the log shows
The ripple stops and the line goes flat
How to tell
Only the pattern shows it
The coldest reading of each day in a Philadelphia freezer, 11 to 22 April 2025. It climbs from about -3°F (-19°C) to 15.6°F (-9.1°C), and TemperatureWise alerts on 20 April.
From the data

The same fault in a Philadelphia walk-in freezer, caught 53 hours before the peak, April 2025

A failed defrost timer leaves the walk-in freezer iced

A walk-in freezer's timer runs a few short defrosts a day to melt the frost off the coil. When the timer fails, the frost stays and builds. Air stops moving through the coil, and each day ends a little warmer than the last.

How fast
Over days
What the log shows
The coldest point of each day steps up
TemperatureWise
Alerted 53 hours before the peak. One visit fixed it
Two views of a freezer's cooling coil. On the left the coil is clear and air flows through it. On the right, warm, wet air through a propped door has frozen onto the coil and the defrosts cannot clear it as fast as it builds, so the air stops at the coil.
In their words

"Walked in after a day closed and the freezer was at 50 degrees [50°F (10°C)]"

r/KitchenConfidential, thread title

A door left open, a torn gasket, a curtain taken down

In that thread a manager had left the freezer open to grab a water bottle, and about $1,000 of stock was lost. A door that does not close lets in warm, wet air for hours. Over days it ices the coil, and each day ends warmer.

How fast
Minutes to let the air in, days to ice the coil
What the log shows
Warm while the door is open, then warmer each day
How to tell
Humidity rises with it

A threshold alarm goes off for these every day. TemperatureWise learns them in its first week.

The rush, deliveries and defrosts move a walk-in's temperature on every working day. None of them is a failure.

A threshold alarm

Sounds whenever a walk-in crosses one fixed line. On the coffee shop walk-in above, a 41°F (5°C) alarm with a 30-minute delay would have gone off on 39 of 46 days, almost always from the door, and stayed silent the night the box was stuck. More in what to set a walk-in cooler alarm to.

TemperatureWise

Learns each walk-in's normal pattern in its first week: its busy hours, its deliveries and its defrosts. It stays quiet for the routine and alerts when a box stops behaving like itself, like the three failures above.

Three ordinary days in a busy walk-in cooler, 10 to 12 March 2026. At night the air sits near 35°F (2°C) with a small ripple. By day it spikes several times, to between 39°F and 47°F (4°C and 8.5°C), when the door is open, and each spike comes back down.
Door spikes By day the door spikes the air again and again, and each spike comes back down.
A restaurant day from 10 AM to midnight with a lunch rush and a dinner rush. The walk-in door opens again and again during each rush, and the box runs warmer, then recovers after service. That is normal, and TemperatureWise learns it.
The rush The walk-in door opens again and again at lunch and dinner. The box runs warmer, then recovers.
A delivery truck unloading into a walk-in cooler. The door is open while cases go in, and the new stock arrives a little warmer than the box, so the walk-in warms for a while and then pulls back down. That is normal, and TemperatureWise learns it.
Deliveries The door stays open while cases go in, and the walk-in warms for a while.
Line chart of a walk-in freezer on 11 April 2025. It runs near -0.4°F (-18°C) all morning. At midday a scheduled defrost lifts it to a peak of 22.1°F (-5.5°C), crossing a dashed alarm line at 10°F (-12°C) for 55 minutes, then it drops back to normal by early afternoon.
Defrosts A defrost warms the air for a short time, several times a day. The food stays cold.

Where the sensor goes

Five places a sensor gets mounted in a walk-in, and the one that answers the inspector

A cut-through of a walk-in with five sensor positions: in the coil's discharge air, on the ceiling, beside the door, on a shelf among the stock at product height, and in the return air at the coil inlet.

What each place reads

  1. The coldest air in the room. It flatters the box.
  2. The warm layer, and it gets dripped on during defrost.
  3. Every door opening.
  4. What the food sees, at product height. The one that answers the inspector's question.
  5. The best single place to watch the equipment.

A small walk-in gets one sensor, a mid-sized one two, and a large one three, at the height the product sits. More in where to put a sensor in a walk-in.

Pricing and payback

Two walk-ins cost $1,050 up front and $1,000 a year

A walk-in cooler and a walk-in freezer, two sensors each

ItemOncePer year
4 LoRa sensors at $200$800
Gateway for a mid-sized site$250
Monitoring, 4 sensors at $250$1,000
Total$1,050$1,000

On your own internet, so connectivity is free. A large site with three walk-ins, cellular and battery backup is $2,500 up front and $2,300 a year. Price list of 1 September 2026.

All prices, and examples for many sites

One saved walk-in load pays for a year

In an r/KitchenConfidential thread, a freezer door left open on a closed day cost about $1,000 of stock. That is the yearly fee for two walk-ins.

Monitoring is $250 per sensor per year, about $21 a sensor a month. A walk-in usually holds more than one bad night's worth of stock, and the fee stays the same however full it is.

The $1,000 figure is from one r/KitchenConfidential thread, as recorded in our research. Your own stock value goes in the calculator below.

Want a detailed calculation for your own site? The full calculator on the TemperatureWise page takes your rooms, sensors and connection.

Open the full calculator

How it works

Three steps, nothing drilled, no shutdown

  1. We plan it from your floor plan

    TemperatureWise marks where each sensor and the gateway go before anything ships.

  2. You place the sensors and plug in the gateway

    Magnet, adhesive pad or one screw. The gateway goes into an ordinary socket.

  3. It learns each unit in the first week

    TemperatureWise learns each unit's defrost pattern and sets alerts around it, so a normal defrost is not an alarm.

The Renergy gateway, a white desktop unit with a whip antenna.
In the officeThe gateway sits on a shelf, plugged into an ordinary socket.
LoRa radio through walls and walk-in panels. Nothing drilled.
Looking up at the evaporator inside a loaded walk-in cooler, with its fans below the ceiling and cartons stacked on wire shelving in the foreground.
In the walk-inThe sensor goes on a shelving upright near the door, not in the fans' cold air.
Every 15 minutesReadings kept indefinitely
Rated to -40°F (-40°C)Battery lasts 5 to 8 years
Temperature and humidityFrom one sensor

The rules

The temperatures US and Ontario inspectors check in a walk-in

US · FDA Food Code

Cold food is held at 41°F (5°C) or colder, and food stored frozen stays frozen. Most states adopt the Food Code, some with their own changes.

Read the FDA Food Code

US · USDA FSIS

Food stored constantly at 0°F (-18°C) will always be safe. Time at 0°F affects quality, not safety.

Read USDA's freezing guidance

Ontario · O. Reg. 493/17

Cold food is held at 4°C (39°F) or colder (s. 27), in equipment with an accurate thermometer that is easy to read (s. 30).

Read O. Reg. 493/17

The inspector sees the day of the visit. TemperatureWise keeps the nights, weekends and closed days in between. The sign-off stays with you.

Common questions

How much does walk-in cooler monitoring cost?

$1,050 up front and $1,000 a year for two walk-ins with two sensors each, on your own internet: $200 a sensor, a $250 gateway, and $250 per sensor per year. A large site with three walk-ins, cellular and battery backup is $2,500 up front and $2,300 a year. The dashboard, alerts and setup cost nothing extra.

What should a walk-in cooler alarm be set to?

41°F (5°C) is the Food Code line, 4°C (39°F) in Ontario, but a busy walk-in crosses it with the door, so a fixed alarm there goes off most days and stays quiet when a box is stuck just under it. TemperatureWise alerts on the box's own pattern instead. More in walk-in cooler alarm: what to set it to.

Where should the sensor go in a walk-in?

On a shelf among the stock, at the height the product sits, out of the coil's discharge air. A sensor in the cold air off the coil reads better than the food really is, which is the most common mistake.

Will the signal get out through the walk-in walls?

Yes. TemperatureWise's LoRa radio passes through walk-in panels and several walls to one gateway, so nothing is drilled through the insulation. Wi-Fi often does not get through a freezer panel. More in will wireless work through a freezer wall.

Do I need different sensors for a walk-in cooler and a walk-in freezer?

The sensor comes in a cooler version and a freezer version. The freezer version is rated to -40°F (-40°C) and reads humidity too, which shows a failing door seal or an icing coil before the temperature moves. Both are $200 and $250 a year.

How often should walk-in temperatures be checked?

Every 4 hours while you are open, or at opening and closing, under common plans, and food on the line every 2 hours. The FDA Food Code sets no fixed interval, so your health department or HACCP plan decides. Ask your inspector.

Between checks, and all night, nobody is looking. TemperatureWise records each walk-in every 5 or 15 minutes, depending on the sensor, and phones someone when one warms. More in how often to log fridge and freezer temperatures.

See what your walk-ins have been doing

Send us 30 days of readings from one walk-in, or let us put a sensor in it. We will show you what it was doing before anyone noticed. No purchase needed.

Sources for every figure on this page
  1. Prices, sensor specifications and alert steps: the TemperatureWise price list of 1 September 2026
  2. The walk-in that stopped cycling, and the 39 of 46 days: walk-in cooler troubleshooting. The three ordinary days: how a walk-in cooler works
  3. The failed defrost timer: the Philadelphia freezer case study. The propped door and the $1,000 loss: an r/KitchenConfidential thread, as recorded in Renergy's research thread index
  4. The five sensor places: where to put a sensor in a walk-in
  5. How often to check: the FDA Food Code asks for daily oversight of temperature checks with no fixed interval (2-103.11), and a Northern Nevada Public Health sample procedure checks cold holding units at least every 4 hours and food on a line every 2 hours, both set out on how often to log fridge and freezer temperatures
  6. US: the FDA Food Code and USDA FSIS, freezing and food safety. Ontario: O. Reg. 493/17, s. 27 and s. 30
  7. The three case studies at the foot of the page: the Philadelphia freezer, the dual-system freezer and the Mississauga stationary reefer

Last reviewed 16 November 2026