TemperatureWise for freezers

Freezer temperature monitoring and alarm system

Know a freezer is failing days before the stock thaws. TemperatureWise is a freezer temperature monitoring and alarm system: a wireless sensor rated to -40°F (-40°C) in each walk-in, reach-in or chest freezer, a reading every 15 minutes, and alerts on your phone that climb until someone answers. A walk-in freezer and a reach-in freezer cost $850 up front and $750 a year.

  • Walk-in freezers
  • Reach-in and undercounter freezers
  • Chest and display freezers
  • Freezer rooms
A TemperatureWise sensor clipped to the upright of a pallet rack inside a loaded freezer, covered in frost.
53 hoursof warning before a freezer's failed defrost timer peaked
53 hoursof warning before a failed defrost timer peaked. $0 lostPhiladelphia, April 2025
27 daysof warning before a $450,000 freezer repairPhiladelphia distribution center, 2025
-40°F (-40°C)the freezer sensor's rating, with a battery that lasts 5 to 8 yearsTemperatureWise sensor specification
An animated drawing of how TemperatureWise readings travel. Inside the cold box, a sensor clipped to a shelf takes a reading and sends it by radio through the wall, with nothing drilled, to the gateway on site. The gateway passes it over the internet or cellular to the Renergy cloud, where AI watches every reading, and the cloud puts it in the app as a new point on the chart. Green readings travel one after another. Then one reading comes in too warm and turns red: the cloud flags it, the app plots it above the line, and an alert goes to a phone, first as an email, then a text, then a phone call, until someone answers.

What you get

Four things TemperatureWise does as a freezer monitoring and alarm system

The TemperatureWise app showing a portfolio with a receiving dock, a blast cell and a freezer hall, each with its latest reading.Illustrative data

Every freezer, on your phone

See every walk-in, reach-in and chest freezer from anywhere, with the latest reading and the trend. Each alert names the freezer.

The four links between a freezer sensor and your phone. The sensor runs on its own battery and keeps reading in a power cut. The gateway and your internet run on mains and go down. The cloud and the mobile network keep running, so the alert is raised there.

A power cut on a closed day still reaches you

The sensors run on their own batteries. If a power cut takes down the gateway or your internet, the TemperatureWise cloud notices the silence and alerts you.

What happens when the power goes out
The TemperatureWise app showing a temperature trend chart for one unit over a 24 hour period.Illustrative data

The log fills itself in

Every reading is kept, so the record covers the nights and the days you were closed, not only the times somebody wrote a number down.

TemperatureWise alert settings with three steps: email, then a text message, then a phone call, each after a delay.Illustrative data

Alerts climb until someone answers

Email, then a text, then a call, to up to three people for each sensor. A Sunday fault reaches the manager, then the owner.

Where it goes wrong

Three freezer failures worth an alert, and the daily ups and downs that aren't

A freezer warms a little at every defrost and every load. The job is to tell those from the start of a failure, days before the stock is at risk.

The coldest reading of each day in a Philadelphia freezer, 11 to 22 April 2025. It climbs from about -3°F (-19°C) to 15.6°F (-9.1°C), and TemperatureWise alerts on 20 April.
From the data

The same fault in a Philadelphia walk-in freezer, caught 53 hours before the peak, April 2025

A failed defrost timer leaves the freezer iced

A freezer's timer runs a few short defrosts a day to melt the frost off the coil. When the timer fails, the frost stays and builds. Air stops moving through the coil, and each day ends a little warmer than the last.

How fast
Over days
What the log shows
The coldest point of each day steps up
TemperatureWise
Alerted 53 hours before the peak. One visit fixed it
The refrigeration loop: the coil in the freezer, the compressor, the condenser outside and the expansion valve, joined by pipes. A slow leak at a joint means less refrigerant each week, longer run times and a warmer daily low.
From the data

Caught 27 days before the first repair in Philadelphia, June 2025

A slow refrigerant leak takes weeks to show

Each week there is a little less refrigerant to carry heat out. The room runs longer, and its coldest point of the day creeps up and does not come back.

How fast
1 to 8 weeks
What the log shows
The daily low creeps up
How to tell
Run times grow too. A technician confirms with pressures
Two views of a freezer's cooling coil. On the left the coil is clear and air flows through it. On the right, warm, wet air through a propped door has frozen onto the coil and the defrosts cannot clear it as fast as it builds, so the air stops at the coil.
In their words

"Walked in after a day closed and the freezer was at 50 degrees [50°F (10°C)]"

r/KitchenConfidential, thread title

A door left open, a torn gasket, a curtain taken down

In that thread a manager had left the freezer open to grab a water bottle, and about $1,000 of stock was lost. A door that does not close lets in warm, wet air for hours. Over days it ices the coil, and each day ends warmer.

How fast
Minutes to let the air in, days to ice the coil
What the log shows
Warm while the door is open, then warmer each day
How to tell
Humidity rises with it

A threshold alarm goes off for these every day. TemperatureWise learns them in its first week.

Defrosts, loads of warmer stock and door traffic move a freezer's temperature every day. None of them is a failure.

A threshold alarm

Sounds whenever a freezer crosses one fixed line. A normal defrost crosses it, so it goes off every day and staff learn to ignore it. In one real walk-in freezer log, a normal defrost set it off for 55 minutes. More in why temperature alarms cry wolf.

TemperatureWise

Learns each freezer's own defrost schedule, loads and door traffic in its first week. It stays quiet for the routine and alerts when the freezer stops behaving like itself, like the three failures above.

Line chart of a walk-in freezer on 11 April 2025. It runs near -0.4°F (-18°C) all morning. At midday a scheduled defrost lifts it to a peak of 22.1°F (-5.5°C), crossing a dashed alarm line at 10°F (-12°C) for 55 minutes, then it drops back to normal by early afternoon.
Defrosts A defrost warms the air for a short time, several times a day. The food stays frozen.
Two views of a freezer doorway. During a shift the strip curtain is tied back and pallet jacks go in and out, bringing warm, wet air in with every pallet, so the room runs warmer. After the shift the curtain is down, the doors are shut and the room recovers.
Door traffic Doors and pallet jacks warm a freezer room on shift. It recovers once the doors stay shut.
Three boxes in a row: production, the shock freezer and the holding freezer. Product moves from one to the next. Each load warms the holding freezer a little, and the room then pulls back down. That is normal, and TemperatureWise learns how long each room takes to recover.
Warm loads Each load of new stock warms the freezer for a while, then it pulls back down.
Two views of a freezer coil. After washdown, moist air reaches the coil and leaves a light frost on it. The next scheduled defrost clears it. That is normal. It only becomes a problem when frost builds faster than defrost can clear it.
Frost after cleaning Cleaning leaves moisture in the air and a light frost on the coil. The next defrost clears it.

Real failures, real numbers

One freezer failed twice in 2025, and TemperatureWise caught it both times

Two charts of the coldest reading each day in one Philadelphia freezer. In April 2025 it climbs for a week and an alert comes 53 hours before a failed defrost timer is replaced. In June and July 2025 it climbs for weeks and the first warning comes 27 days before repairs begin.

The June failure, step by step

  1. TemperatureWise alerts the team to a developing problem. The room can still reach about 6.8°F (-14°C).
  2. TemperatureWise's AI diagnoses a refrigerant leak and alerts the team.
  3. First repair. One of the two systems is back.
  4. $450,000 of stock moved to a temporary reefer. Final repair.
  5. Stable again near the -0.4°F (-18°C) target.

"Without your timely interference, things could have gone sideways. It turned out to be a great save."

Operations Manager, frozen smoothie brand

All three case studies are at the end of the page. The same freezer is on the cold storage page.

Pricing and payback

A walk-in freezer and a reach-in freezer cost $850 up front and $750 a year

A walk-in freezer and a reach-in freezer

ItemOncePer year
3 LoRa freezer sensors at $200$600
Gateway for a mid-sized site$250
Monitoring, 3 sensors at $250$750
Total$850$750

Two sensors in the walk-in freezer and one in the reach-in, on your own internet. Cellular is $125 once and $50 a year, and battery backup is $125 once and needs cellular. Price list of 1 September 2026.

All prices, and examples for many sites

One freezer failure costs more than a lifetime of monitoring

Before it had monitoring, a frozen smoothie brand lost $125,000 of stock in one Sacramento freezer over a long weekend, with nobody on site. A year of TemperatureWise for the two freezers above is $750.

That loss is more than 160 times the yearly fee. Monitoring is $250 per sensor per year, about $21 a sensor a month, and it stays the same however full the freezer is.

The $125,000 is the brand's own figure, before it became a customer. Your own stock value goes in the calculator below.

Want a detailed calculation for your own site? The full calculator on the TemperatureWise page takes your rooms, sensors and connection.

Open the full calculator

How it works

Three steps, nothing drilled, no shutdown

  1. We plan it from your floor plan

    TemperatureWise marks where each sensor and the gateway go before anything ships.

  2. You place the sensors and plug in the gateway

    Magnet, adhesive pad or one screw. The gateway goes into an ordinary socket.

  3. It learns each freezer in the first week

    TemperatureWise learns each freezer's defrost pattern and sets alerts around it, so a normal defrost is not an alarm.

The Renergy gateway, a white desktop unit with a whip antenna.
In the officeThe gateway sits on a shelf, plugged into an ordinary socket.
LoRa radio through walls and freezer panels. Nothing drilled.
Looking up at the evaporator inside a loaded walk-in cooler, with its fans below the ceiling and cartons stacked on wire shelving in the foreground.
In the walk-inThe sensor goes on a shelving upright near the door, not in the fans' cold air. Shown here in a walk-in cooler.
Every 15 minutesReadings kept indefinitely
Rated to -40°F (-40°C)Battery lasts 5 to 8 years in a deep freezer
Temperature and humidityFrom one sensor

The rules

What US rules ask of a freezer

US · USDA FSIS

What they want. Food stored constantly at 0°F (-18°C) will always be safe. Time at 0°F affects quality, not safety.

TemperatureWise: A reading every 15 minutes shows whether a freezer left 0°F (-18°C), when, and for how long.

Read USDA's freezing guidance

US · FDA Food Code

What they want. Food stored frozen stays frozen (3-501.11). Most states adopt the Food Code, some with their own changes.

TemperatureWise: An alert when a freezer starts to warm out of its pattern, before anything thaws.

Read the FDA Food Code

US · 21 CFR 117.206

What they want. A warehouse storing packaged food that needs temperature control monitors the temperature, acts when it goes wrong, and keeps records.

TemperatureWise: The record, and the corrective action staff log against each alert, kept indefinitely.

Read 21 CFR 117.206

TemperatureWise produces the record. The review and sign-off stay with you.

Common questions

How much does a freezer temperature monitoring system cost?

$850 up front and $750 a year for a walk-in freezer with two sensors and a reach-in freezer with one, on your own internet: $200 a sensor, a $250 gateway, and $250 per sensor per year. Cellular adds $125 once and $50 a year. The dashboard, alerts and setup cost nothing extra.

What temperature should a commercial freezer be?

0°F (-18°C) or colder. USDA says food stored constantly at 0°F will always be safe, and that time at that temperature affects quality, not safety. The FDA Food Code asks that food stored frozen stays frozen.

Will a freezer alarm go off during a defrost?

A fixed alarm often does. In one real walk-in freezer log, a normal defrost lifted the air to 22.1°F (-5.5°C) and kept it above a 10°F (-12°C) alarm line for 55 minutes. TemperatureWise learns each freezer's defrost schedule in its first week and stays quiet for it.

Does the sensor work inside a freezer?

Yes. The freezer version is rated from -40°F to 131°F (-40°C to 55°C). Its lithium cells last 5 to 8 years in a deep freezer at a reading every 15 minutes, with 4 years guaranteed. Its LoRa radio passes through the insulated panels, so nothing is drilled. More in will wireless work through a freezer wall.

Can it monitor an ultra-low freezer at -80°C?

Not today. The sensor's range stops at -40°F (-40°C), so a lab freezer at -80°C (-112°F) is outside it. Ask us before you buy for one.

What happens if the power goes out?

The sensors run on their own batteries and keep reading. If the power cut takes down the gateway or your internet, the TemperatureWise cloud notices the silence and alerts you. With cellular and battery backup, the gateway keeps sending through the outage. More in what happens when the power goes out.

See what your freezers have been doing

Send us 30 days of readings from one freezer, or let us put a sensor in it. We will show you what it was doing before anyone noticed. No purchase needed.

Sources for every figure on this page
  1. Prices, sensor specifications and alert steps: the TemperatureWise price list of 1 September 2026. The freezer sensor's range, accuracy and battery: the specification table on the TemperatureWise page
  2. The failed defrost timer: the Philadelphia freezer case study. The refrigerant leak: the dual-system freezer case study
  3. The propped door quote: an r/KitchenConfidential thread title, as recorded in Renergy's research thread index. The Sacramento loss: the brand's own figure, on the TemperatureWise page
  4. The 55-minute defrost: why temperature alarms cry wolf
  5. US: USDA FSIS, freezing and food safety, the FDA Food Code (3-501.11) and 21 CFR 117.206
  6. The three case studies at the foot of the page: the Philadelphia freezer, the dual-system freezer and the Mississauga stationary reefer

Last reviewed 16 November 2026