TemperatureWise pricing

TemperatureWise pricing: what a temperature monitoring system costs

TemperatureWise costs $250 per sensor per year, about $21 a sensor a month, plus one-time hardware: a sensor at $25 or $200, and one gateway or hub per site at $100 to $450. The dashboard, alerts and setup cost nothing extra. A small restaurant pays $175 up front and $750 a year. Ten restaurants with two walk-ins each pay $10,500 up front and $10,000 a year at list price.

The Renergy gateway, a white desktop unit with a whip antenna.
$21a sensor a month, dashboard and alerts included
$250 a yearper sensor, about $21 a monthMonitoring
$175 up frontfor the smallest site: three reach-ins on your own Wi-FiWorked example
$0for the dashboard, alerts and setupIncluded

The price list

Every price, from the 1 September 2026 price list

In US dollars. Hardware is paid once; monitoring and cellular are yearly.

ItemOncePer year
Monitoring
Monitoring, per sensorAbout $21 a month. The dashboard, alerts, setup and records are included$250
Door contact monitoringAlongside temperature monitoring, half price. $250 a year on its own$125
Sensors
LoRa sensorWalk-ins, freezers and sites that sprawl. Temperature and humidity, a reading every 15 minutes, battery 5 to 8 years. A cooler version and a freezer version rated to -40°F (-40°C)$200
Bluetooth entry sensorSmall kitchens and stores with the boxes close together, near a hub. A reading every 5 minutes, battery about 2 years$25
Door contactEach opening and closing, on that room's chart. Consumables and installation included$40
On site, one per location
Gateway or hub, smaller site$100
Gateway, mid-sized site$250
Gateway, larger siteThe strongest unit. One gateway reaches across several buildings$450
Your own Wi-Fi or Ethernet$0$0
Cellular connectionWhere the site network is off limits$125$50
Battery backupA mini-inverter that keeps the gateway running in a power cut. Needs the cellular package$125
Quoted for your site
Probe in a glycol bottle, and a NIST traceable calibration certificateFor the stock temperature rather than the air, as vaccine programs askQuoted
BACnet gatewayPuts the readings into a BMS or BAS as ordinary pointsQuoted
Sensors you already ownOften connectable, with the same alerts and recordsQuoted
Your history from another systemImported, and read for equipment that is failing now or was repaired beforeFree

Worked examples

What one site costs, from each solutions page

Each example is the one on that page, at list price. Cheapest first.

Page and exampleUp frontPer year
TemperatureWise pageA small restaurant with three reach-ins on its own Wi-Fi$175$750
RefrigeratorsSix reach-ins and undercounters on the entry sensors$250$1,500
Convenience storesOne store: a beer cave and six other cabinets$300$2,000
Reefer trailersOne trailer, a sensor at the nose and one at the tail$775$550
FreezersA walk-in freezer and a reach-in freezer$850$750
PharmaciesTwo fridges and a freezer$950$800
Restaurants and food serviceA mid-sized restaurant with two walk-ins$1,050$1,000
Walk-in coolers and freezersA walk-in cooler and a walk-in freezer, two sensors each$1,050$1,000
School kitchensTwo walk-ins, two reach-ins and a milk cooler$1,775$1,800
WarehousesA freezer hall, a cooler and an ambient zone, two sensors each$1,900$1,550
Cold storage and 3PLThree large rooms, three sensors each$2,500$2,300
Healthcare kitchensTwo walk-ins, two roll-ins and four unit fridges$2,700$2,550
Hotel kitchensA banquet kitchen, a restaurant, room service and three bars$2,975$3,050
Grocery storesFour rack groups and three walk-ins$3,500$3,550
Food manufacturing and cateringTwelve cold rooms, two sensors each$5,500$6,050

Many sites, or one big one

Ten restaurants, or a cold store with twelve rooms

At list price. Multi-site and large deployments are quoted, and the price list notes that further discounts depend on the deployment.

A group of 10 restaurants, two walk-ins each

ItemOncePer year
40 LoRa sensors at $200$8,000
10 gateways for a mid-sized site, at $250$2,500
Monitoring, 40 sensors at $250$10,000
Total$10,500$10,000

Each site needs its own gateway, on its own internet. Every site shows on one screen, with alerts that name the site and the box. One site alone is $1,050 up front and $1,000 a year.

A cold store with 12 rooms, three sensors a room

ItemOncePer year
36 LoRa sensors at $200$7,200
Gateway for a larger site$450
Cellular connection$125$50
Battery backup$125
Monitoring, 36 sensors at $250$9,000
Total$7,900$9,050

One gateway reaches across several buildings; the walkthrough before install confirms it covers every room. With two sensors a room, as on the food manufacturing page, it is $5,500 up front and $6,050 a year. The three-room version is on the cold storage page: $2,500 up front and $2,300 a year.

Included

What every sensor's $250 a year includes

The app and dashboard

Every site and every unit on one screen, on iPhone, Android and the web.

Alerts that climb

Email to as many people as you want, then SMS and phone calls to up to 3 people per sensor, until someone answers.

A silent sensor is an alert too

A sensor or gateway that stops reporting raises an alert, the same way a temperature does.

Records kept indefinitely

Every reading, with the corrective action staff record against each alert. An audit trail for HACCP, BRC and SQF.

Setup

We plan where each sensor and the gateway go from your floor plan, before anything ships.

A battery guarantee

The LoRa sensor's battery is guaranteed for 4 years. If one does not last, we replace it free.

Want the number for your own site? The calculator on the TemperatureWise page takes your rooms, sensors and connection, and what your stock is worth.

Open the calculator

Common questions

How much does a temperature monitoring system cost?

TemperatureWise is $250 per sensor per year, plus one-time hardware: $25 or $200 a sensor and one gateway or hub per site at $100 to $450. A small restaurant with three reach-ins pays $175 up front and $750 a year. Two walk-ins are $1,050 up front and $1,000 a year.

Is there a monthly fee?

Monitoring is $250 per sensor per year, which is about $21 a sensor a month. There is no separate charge for the app, the dashboard, the alerts or setup.

Do I need a gateway at every site?

Yes, one per location: $100 for a smaller site, $250 for a mid-sized one and $450 for a larger one. One gateway reaches across several buildings on the same site, so a bigger site mostly adds sensors.

Is there a discount for many sites?

Multi-site and large deployments are quoted. The price list notes that further discounts depend on the deployment. The examples on this page are all at list price.

What does it cost if the site has no Wi-Fi?

A cellular connection is $125 once and $50 a year. Battery backup for the gateway is $125 once and needs the cellular package, so alerts keep going out through a power cut.

Can I use the sensors I already have?

Often, yes, with the same alerts and records. If you are switching from another system, we import your full history free and read it for equipment that is failing now or was repaired in the past. Ask about your setup.

Do you answer security questionnaires and RFPs?

Yes, in writing. The network, encryption, BACnet and alert answers most RFPs ask for are on TemperatureWise for IT and procurement, with a one-page summary to download.

What does a door contact cost?

$40 per door once, including consumables and installation, and $125 per door per year alongside temperature monitoring, half the $250 standalone price. Plan on a battery change about every 2 years.

Get a quote for your sites

Send us your sites and what each one holds. We will plan the sensors and the gateways, and quote the whole network.

Sources for every figure on this page
  1. Every price and the sensor details: the TemperatureWise price list of 1 September 2026, as the specification table on the TemperatureWise page gives it (checked 18 October 2026)
  2. The worked examples: the pricing block on each solutions page linked in the table
  3. The probe and calibration certificate being quoted separately: the pharmacy page

Last reviewed 16 November 2026