For IT, facilities and procurement
TemperatureWise for IT and procurement
TemperatureWise can stay off your network. Each sensor sends by radio to one gateway per site, coded end to end, and the gateway can send over its own cell link, so nothing joins your network. The readings can also show up as plain BACnet points in your building system. This page answers the questions IT and buying teams ask, with a one-page summary to download.

The network
How the readings get out, and what it asks of your network
The radio
Each sensor sends over LoRaWAN, 902 to 928 MHz in North America, through walls and freezer panels to one gateway for the site. Nothing is drilled, and nothing needs your Wi-Fi to reach inside a freezer.
Getting out
The gateway uses your own Wi-Fi or a cable at no charge. If the site network is off limits, the cell package is $125 once and $50 a year a site, and nothing joins your network.
A power cut
Sensors run on their own batteries. A small backup unit keeps the gateway running, and needs the cell package. A sensor or gateway that goes quiet sets off an alert, the same as a warm room.
What happens when the power goes outSystems you already run
Into your building system, your ticketing and your contractor's dispatch
A BMS or a BAS
With the BACnet gateway the readings show up as plain BACnet points, beside all else your facilities team already watches.
Ticketing and dispatch
Alerts can go to a ticket system by email, or be sent into your dispatch or ticket software by API or webhook. A service firm can have one login for every site it looks after.
For refrigeration contractorsSensors you already own
TemperatureWise can often read the sensors you already have. If you switch from another system, we bring your full history over free.
RFP checklist
The questions to put to any vendor, with our answers
Copy the left column into your own RFP. Where our answer is "ask us", we answer in writing for your review.
| Question | TemperatureWise |
|---|---|
| Sensor radio, and does it need our Wi-Fi? | LoRaWAN, 902 to 928 MHz, to one gateway per site. No Wi-Fi inside the cold rooms. A Bluetooth tier suits small kitchens with the units close together |
| Encryption | Diffie-Hellman key exchange with AES-128 CBC, end to end |
| Does anything join our network? | Not with the cellular package. Otherwise the gateway uses your Wi-Fi or Ethernet |
| Reading interval and record | Every 15 minutes on the LoRa sensor, every 5 on the Bluetooth sensor. Kept indefinitely, with staff's corrective actions |
| Measurements and range | Temperature and humidity in one sensor. Freezer version -40°F to 131°F (-40°C to 55°C), ±0.3°C (±0.54°F) and ±2% RH at 77°F (25°C) |
| Alerts and escalation | Email to any number of people; SMS and phone calls to up to 3 people per sensor, escalating until someone answers. A silent sensor or gateway raises an alert |
| Integration | BACnet points for a BMS or BAS; alerts by API or webhook, or by email into ticketing |
| Data export | Your readings export as a spreadsheet file. Your history from another system is imported free |
| Power cut | Sensors on their own batteries; a backup mini-inverter for the gateway with the cellular package |
| Battery life | LoRa sensor 5 to 8 years in a deep freezer, 4 years guaranteed; Bluetooth sensor about 2 years |
| Calibration | NIST-traceable calibration certificates, quoted on request |
| Installation | Planned from your floor plan; no electrician and nothing drilled. A mid-sized restaurant takes 30 to 60 minutes |
| Pricing | Published: $250 per sensor per year; sensors $25 or $200; one gateway or hub per site at $100 to $450. Multi-site deployments quoted |
| Security questionnaire, hosting and certifications | Ask us, and we answer your questionnaire in writing |
Every answer is from the specification table and price list on the TemperatureWise page, price list of 1 September 2026.
For procurement
What makes TemperatureWise easy to buy
Prices are published
Every price is on one page, with worked examples for one site and for many. A quote for a large rollout starts from those figures.
TemperatureWise pricingNo server, no licence
One yearly fee per sensor covers the dashboard, alerts, setup and records. There is no server to run and no license on top.
Proof you can check
Three case studies post their raw readings, and the saves log dates every alert that saved stock.
The saves logCommon questions
No, not with the cell package: the gateway sends over its own cell link, $125 once and $50 a year a site, and nothing joins your network. Without it, the gateway uses your Wi-Fi or a cable at no charge.
With a Diffie-Hellman key exchange and AES-128 CBC encryption, end to end.
Yes. With the BACnet gateway the readings show up as plain BACnet points in your BMS or BAS.
Yes, by email into the ticket system, or sent by API or webhook. Alerts also go by email, text and phone call to the people you choose.
Yes. Your readings export as a spreadsheet file, and if you switch from another system we bring its full history over free.
With the cell package, nothing. If not, a network port or Wi-Fi for one gateway per site. We plan where the sensors and the gateway go from your floor plan before anything ships.
Send us your questionnaire
Send your RFP or security list and we will answer it in writing, or book a call with your IT and facilities teams together.