Refrigerator temperature mapping
Refrigerator temperature mapping, for every fridge from under-counter to double-door
We ship calibrated sensors for your fridge, and you place them with us on a video call: at the corners, the center and one outside. The readings reach us live, and the signed report comes 2 business days after the 3-day study.
- 4 to 19 sensors
- 3-day study
- No site visit
- Report in 2 business days
How it works
From your refrigerator to a signed report, live
Packages
Every price, posted. Pick your unit.
US dollars, before tax, for a remote study. Shipping at the carrier's rate, no markup. On-site service and -80°C (-112°F) freezers are quoted separately.
Keep some of the sensors after the study, and you have continuous monitoring for $250 a sensor a year.
See TemperatureWiseOrdering
Four steps, no site visit
Pick a package
By unit size, with a date.
Approve the protocol
On a call, before we ship.
Place sensors on video
We check each spot with you.
Get the signed report
2 business days after the study.
Need more hands-on help? We also offer assisted installation, up to full white-glove service, quoted separately.
Talk with usThe report
The report fills in while the study runs
The method
How a refrigerator temperature mapping study runs
Where the 4 to 19 sensors go
A compact fridge takes 4: two opposite corners, the center and one outside for the room air. A single-door upright takes 10: all eight corners, the center and one outside. A double-door takes 19: the corners and the center of each side, and one outside.
3 days, so every cycle repeats
A fridge runs in cycles: the compressor starts and stops, and many fridges defrost on a timer. Three days catches each cycle more than once, so the map can tell a normal swing from a warm spot. Pharmacy fridge mapping often runs over 48 hours.
Empty, full or both
A loaded fridge holds temperature differently from an empty one. The protocol says which you want mapped. Health Canada's guidance for drug storage maps fridges both ways.
The door test sets how long a door may stand open
With your agreement, the protocol holds the door open for a set time. The map shows how long the fridge takes to recover, which tells staff how long a door may stand open while they load.
The power test shows how long you have
The protocol can also switch the fridge off for a set time. The map shows how long it holds in a power cut before product is at risk.
What the report holds
The lowest, highest and average reading at every sensor, the warm and cold spots, the door and power results, the mean kinetic temperature, any reading outside the range, where the permanent probe should go, the calibration certificates and the raw data. A certified Renergy engineer reviews and signs it.
Who asks
Who asks for a fridge map
Hospitals and blood banks
AABB expects each blood fridge to be validated before use. Pharmacy and lab fridges are mapped when an accreditor, a trial sponsor or a new unit asks.
Hospital temperature mappingVaccine storage
The CDC puts a vaccine fridge's buffered probe in the center of the unit, among the vaccines. A map shows whether the center reads like the rest of the fridge.
CDC monitoring equipmentCanada
Health Canada's GUI-0069 asks drug licence holders to map fridges empty and full, long enough to catch the compressor and defrost cycles.
GUI-0069Common questions
A study that places 4 to 19 calibrated sensors through a fridge, by its size, for 3 days, to find its warm and cold spots and how fast it recovers after the door opens. It shows where product is safe and where the permanent probe should go.
$350 for an under-counter fridge, $850 for a single-door upright and $1,600 for a double-door, in US dollars, before tax and shipping. A larger walk-in takes more sensors, and is priced the same way.
4 for a compact fridge, 10 for a single-door upright and 19 for a double-door, each count including one outside the unit for the room air.
3 days in the unit, which catches the compressor and defrost cycles more than once. The signed report comes 2 business days after the study ends.
Both, where you can, because a loaded fridge holds temperature differently. The protocol says which you want, and Health Canada's guidance for drug storage maps fridges both ways.
Where the map shows it reads what your product feels. For vaccines, the CDC puts a buffered probe in the center of the unit, and the report shows whether the center reads like the rest of the fridge.
Yes, it is our default. We ship the sensors with a placement map, and you place them while we check each spot on a video call. The gateway sends the readings over its own cellular link, so nothing joins your network.
Yes. Keep as many as you need and they become continuous monitoring with TemperatureWise, at $250 a sensor a year.
WHO guidance maps a space before it is first used, after any significant change, and on a cycle such as every 3 years.
More temperature mapping
Book a study, or ask what yours would cost
Tell us the unit and the date.