Temperature mapping

Remote temperature mapping by equipment, with every price posted

We ship calibrated wireless sensors for your fridge, cold room, warehouse or vehicle, and your team places them with us on a video call. The readings reach us live, and the signed report comes 2 business days after the study.

  • Every price posted
  • No site visit
  • Report in 2 business days
Every temperature mapping package side by side, each with its glowing sensors: a compact fridge, a single-door upright, a double-door fridge or cold room, a warehouse and a reefer trailer, each with its posted price.
From $350every price postedNone of the 13 sellers we checked posts one
Livereadings while the study runs
2 business daysto the signed report

How it works

From your fridge to a signed report, live

Calibrated sensors at the corners, the center and outside a fridge send their readings by radio to a gateway. The gateway sends them to Renergy live, while the study runs, and the report fills in as they arrive and is signed when the study ends.
Calibrated sensorsCertificates in the report
Own cellular linkNothing joins your network. No IT headache.
Signed by a certified engineerA Renergy engineer with career expertise in cold chain logistics

Packages

Every price, posted. Pick your unit.

A compact under-counter fridge seen through its door, with sensors at two opposite corners and the center, and one outside.

Compact fridge or freezer

Under-counter or bench-top

4 sensors · 3 days

$350

Book
A single-door upright fridge seen through its door, with sensors at all eight corners and the center, and one outside.

Single-door fridge or freezer

A single-door upright

10 sensors · 3 days

$850

Book
A double-door fridge seen through its doors, with sensors at the eight corners and the center of each side, and one outside.

Double-door or small cold room

Or a walk-in up to about 10 ft (3 m) a side

19 sensors · 3 days

$1,600

Book
A warehouse in section, with sensors low, middle and high on every rack, the dock door and the HVAC on the roof, and one outside.

Warehouse

About 10,000 sq ft (930 m²)

30 to 50 sensors · 7 days

$4,750 to $7,900per season

Book
A reefer trailer in section, with sensors at the front wall, the middle and the rear doors, at the floor and near the ceiling, and one outside.

Vehicle

A cube van to a 53 ft trailer

12 to 16 sensors · 2 days each season

$1,400 to $1,850for both seasons

Book

US dollars, before tax, for a remote study. Shipping at the carrier's rate, no markup. On-site service and -80°C (-112°F) freezers are quoted separately.

Keep some of the sensors after the study, and you have continuous monitoring for $250 a sensor a year.

See TemperatureWise

Ordering

Four steps, no site visit

  1. Three package cards with their prices. The single-door fridge is picked.

    Pick a package

    By unit size, with a date.

  2. A video call with two people, and the study protocol beside it, every line checked and approved.

    Approve the protocol

    On a call, before we ship.

  3. A fridge with sensors at its corners, and a phone on a video call confirming that spot 7 looks right.

    Place sensors on video

    We check each spot with you.

  4. The signed report with every section checked, and the sensor kit boxed up to go back.

    Get the signed report

    2 business days after the study.

Need more hands-on help? We also offer assisted installation, up to full white-glove service, quoted separately.

Talk with us

The report

The report fills in while the study runs

A sample temperature mapping report for a single-door vaccine fridge, filling in as the study runs. Each step turns to done: protocol, sensor placement, calibration certificates, the door-open test, the power-off test, the warm and cold spots, where the permanent probe goes, the mean kinetic temperature and raw data, and the review and signature by a certified engineer. Beside them, a picture of each step: the sensors reporting, the door held open, the power cut, the warmest and coldest corners, a pin where the permanent probe goes, the results sheet with its data file, and the signed report with its seal.

By equipment

How each space is mapped

Fridges and freezers: 4 to 19 sensors over 3 days

Sensors go in the corners, the center, by the door and near the fan, with one outside the unit. Three days catches the compressor and defrost cycles. The protocol says whether the unit is mapped empty, full or both, because a loaded unit behaves differently.

Cold rooms: a grid at two heights

The grid grows with the room, and the study adds a door-open test and a power-off test, which show how long the room holds. WHO guidance runs a cold room study for 24 to 72 hours.

Vehicles: real routes, once in each season

Sensors go from the front wall to the doors, floor to ceiling, and the vehicle runs its normal stops, in summer and in winter.

Ultra-low freezers are quoted separately

Freezers at -80°C (-112°F) need sensors rated far colder, so we quote them. A larger space takes more sensors, and is priced the same way, by sensors and days.

Every map ends with where the monitoring should go

Mapping guidance uses the map to decide where the permanent sensors go: at the warmest and coldest spots it finds. Every report names those spots.

The rules

Which rules ask for a map

USP, United States

USP's chapter 1079.4 sets out how to map a drug storage area, for every link that stores or moves a finished drug.

About the chapter

WHO

Maps a space before first use, after a significant change and on a cycle such as every 3 years, and warehouses and vehicles in both seasons.

WHO Supplement 8

Health Canada

GUI-0069 makes mapping a rule for drug licence holders, the 3PLs they contract and their vehicles.

GUI-0069

Common questions

What is temperature mapping?

A study that places many calibrated sensors through a fridge, freezer, cold room, warehouse or vehicle for a set time, to find where it runs warm or cold and how fast it recovers. The result shows where product is safe and where the permanent monitoring sensors should go.

What is fridge temperature mapping?

A study that places 4 to 19 calibrated sensors through a fridge, by its size, for 3 days, to find its warm and cold spots and how fast it recovers after the door opens. Our posted prices are $350 for an under-counter unit, $850 for a single-door upright and $1,600 for a double-door.

How is a freezer mapped?

The same way as a fridge: 4, 10 or 19 sensors by size, at the corners and the center, for 3 days, with a door-open test and, with your agreement, a power-off test. The prices are the same as for a fridge, and a -80°C (-112°F) freezer is quoted separately.

How much does temperature mapping cost?

Our posted prices, in US dollars, for a remote study: $350 for a compact fridge or freezer, $850 for a single-door upright, $1,600 for a double-door unit or a small cold room, $1,400 to $1,850 for a vehicle in both seasons, and $4,750 to $7,900 per season for a 10,000 sq ft warehouse. Shipping is billed at the carrier's rate, with no markup.

Can temperature mapping be done remotely?

Yes, and it is our default across the US and Canada. We agree the protocol on a call, ship calibrated sensors with a placement map, and check each spot on a video call while your team places them. The readings reach us live, and the signed report comes 2 business days after the study ends.

Do you offer on-site temperature mapping?

Yes. Assisted installation and full white-glove service, where a technician places and collects the sensors and runs the tests, are quoted by location. In Ontario and Quebec, travel and installation are free.

Does the kit need our network or IT team?

No. The gateway sends the readings over its own cellular link, so nothing joins your network and there is nothing for IT to set up.

How long does a temperature mapping study take?

Three days for a fridge, freezer or small cold room, two days in each season for a vehicle, and seven days for a warehouse. The signed report comes 2 business days after the study ends.

What is the difference between temperature mapping and temperature monitoring?

Mapping measures many points for days, to learn how a space behaves. Monitoring watches a few points for years, to catch a problem when it happens. The map tells you where the monitoring sensors belong.

How often should temperature mapping be done?

WHO guidance maps a space before it is first used, after any significant change such as new racking, new equipment or a new layout, and on a cycle such as every 3 years. Warehouses and vehicles are mapped in summer and in winter where the seasons matter.

What does a temperature mapping report include?

The lowest, highest and average reading at every sensor, the mean kinetic temperature, the warm and cold spots, recovery times after the door and power tests, any reading outside the range, the calibration certificates, the raw data, and where the permanent sensors should go. A certified Renergy engineer reviews and signs it.

Book a study, or ask what yours would cost

Tell us the unit and the date.