Freezer temperature mapping

Freezer temperature mapping, from under-counter freezers to double-door uprights

We ship calibrated sensors for your freezer, and you place them with us on a video call: at the corners, the center and one outside. The readings reach us live through the defrosts, and the signed report comes 2 business days after the 3-day study.

  • 4 to 19 sensors
  • Defrosts in the map
  • No site visit
  • Report in 2 business days
The freezer mapping packages side by side, each freezer seen through its door with glowing sensors at the corners and the center: a compact freezer with 4 sensors, a single-door upright with 10 and a double-door freezer with 19, each with its posted price. A note says -80°C freezers are quoted separately.
From $350for an under-counter freezer
3 daysseveral defrosts in every map
2 business daysto the signed report

How it works

From your freezer to a signed report, live

Calibrated sensors in a freezer send their readings by radio to a gateway. The gateway sends them to Renergy live, while the study runs, and the report fills in as they arrive and is signed when the study ends.
Calibrated sensorsCertificates in the report
Own cellular linkNothing joins your network. No IT headache.
Signed by a certified engineerA Renergy engineer with career expertise in cold chain logistics

Packages

Every price, posted. Pick your unit.

A compact under-counter freezer seen through its door, with sensors at two opposite corners and the center, and one outside.

Compact freezer

Under-counter or bench-top

4 sensors · 3 days

$350

Book
A single-door upright freezer seen through its door, with sensors at all eight corners and the center, and one outside.

Single-door freezer

A single-door upright

10 sensors · 3 days

$850

Book
A double-door freezer seen through its doors, with sensors at the eight corners and the center of each side, and one outside.

Double-door freezer

Or a freezer room up to about 10 ft (3 m) a side

19 sensors · 3 days

$1,600

Book

US dollars, before tax, for a remote study. Shipping at the carrier's rate, no markup. On-site service and -80°C (-112°F) freezers are quoted separately.

Keep some of the sensors after the study, and you have continuous monitoring for $250 a sensor a year.

See TemperatureWise

Ordering

Four steps, no site visit

  1. Three package cards with their prices. The single-door fridge is picked.

    Pick a package

    By unit size, with a date.

  2. A video call with two people, and the study protocol beside it, every line checked and approved.

    Approve the protocol

    On a call, before we ship.

  3. A fridge with sensors at its corners, and a phone on a video call confirming that spot 7 looks right.

    Place sensors on video

    We check each spot with you.

  4. The signed report with every section checked, and the sensor kit boxed up to go back.

    Get the signed report

    2 business days after the study.

Need more hands-on help? We also offer assisted installation, up to full white-glove service, quoted separately.

Talk with us

The report

The report fills in while the study runs

A sample temperature mapping report for a upright freezer, single door, filling in as the study runs. Each step turns to done: protocol, sensor placement, calibration certificates, door-open test, power-off test, warm and cold spots, where the permanent probe goes, mean kinetic temperature, raw data, review and signature. Beside them, a picture of each step as it happens, ending with the signed report and its seal.

The method

How a freezer temperature mapping study runs

Where the 4 to 19 sensors go

A compact freezer takes 4: two opposite corners, the center and one outside for the room air. A single-door upright takes 10: all eight corners, the center and one outside. A double-door takes 19: the corners and the center of each side, and one outside.

3 days, so the map shows the defrosts

A frost-free freezer heats its coil on a timer, several times a day, and the air near the coil warms each time. Three days catches several defrosts, so the map separates a normal defrost from a spot that is genuinely warm.

Empty, full or both

A full freezer holds its cold longer than an empty one. The protocol says which you want mapped. Health Canada's guidance for drug storage maps freezers both ways.

The door test sets how long a door may stand open

With your agreement, the protocol holds the door open for a set time. The map shows how long the freezer takes to recover, which tells staff how long a door may stand open while they load.

The power test shows how long you have

The protocol can also switch the freezer off for a set time. The map shows how long it holds in a power cut before product is at risk.

-80°C (-112°F) freezers are quoted separately

Ultra-low freezers need sensors rated far colder, so we quote them. Tell us the make and size. A freezer room larger than about 10 ft (3 m) a side is mapped as a cold room.

Who asks

Who asks for a freezer map

Hospitals and blood banks

AABB expects each blood fridge and freezer to be validated before use.

Hospital temperature mapping

Labs and trial sponsors

Lab freezers are mapped when an accreditor, a trial sponsor or a new unit asks.

WHO mapping guidance

Canada

Health Canada's GUI-0069 asks drug licence holders to map freezers empty and full, long enough to catch the compressor and defrost cycles.

GUI-0069

Common questions

What is freezer temperature mapping?

A study that places 4 to 19 calibrated sensors through a freezer, by its size, for 3 days, to find its warm and cold spots, how its defrosts show, and how fast it recovers after the door opens.

How much does freezer temperature mapping cost?

$350 for an under-counter freezer, $850 for a single-door upright and $1,600 for a double-door, in US dollars, before tax and shipping. The same prices as a fridge.

How long does freezer temperature mapping take?

3 days in the unit, which catches several defrosts and the compressor cycles. The signed report comes 2 business days after the study ends.

Does a defrost count as a warm spot?

No. Air near the coil warms during each defrost and cools again after it. Because the study runs 3 days, the map shows the defrosts as a pattern, apart from any spot that is warm all the time.

How many sensors does a freezer mapping study use?

4 for a compact freezer, 10 for a single-door upright and 19 for a double-door, each count including one outside the unit for the room air.

Can you map a -80°C (-112°F) freezer?

Yes. Ultra-low freezers need sensors rated far colder, so we quote them separately. Tell us the make and size.

Can a freezer be mapped remotely?

Yes, it is our default. We ship the sensors with a placement map, and you place them while we check each spot on a video call. The gateway sends the readings over its own cellular link, so nothing joins your network.

Can the sensors stay after the study?

Yes. Keep as many as you need and they become continuous monitoring with TemperatureWise, at $250 a sensor a year.

Book a study, or ask what yours would cost

Tell us the unit and the date.