SQF temperature monitoring and record requirements

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026

This is part 1 of 3 in Food safety standards and temperature records, a short guide to what SQF, BRCGS and FDA each ask of the temperature records for your cold rooms.

SQF asks for three things in a cold room: monitoring equipment at its warmest part, with a display that is easy to read; a written procedure that says how often you check and what you do when a reading is out; and records of the room temperatures. Whoever takes a reading signs it, and whoever reviews it signs and dates it.

The clause numbers here are Edition 9's. Audits use Edition 9 until 2 January 2027, when Edition 10 is expected to take over.

SQF is a certificate your customers ask for, not a law

SQF is a food safety certification. Sites get certified because a buyer asks for it, usually a retailer or a food service company. It is one of the schemes recognised by GFSI, alongside BRCGS and FSSC 22000, so many buyers accept any of them.

SQF has separate Codes for different kinds of site, such as food manufacturing and storage and distribution. The clause numbers on this page are from the Food Manufacturing Code, Edition 9. If a law also applies to you, such as FDA's preventive controls rule, you meet both. See 21 CFR 117 temperature records.

What the Code asks of a cold room

Clause 11.6.2 covers cold storage, freezing and chilling. Here is what it asks, as practitioners quote it. Check the wording against your own copy of the Code.

What SQF Edition 9 asks of cold rooms, freezers and chillers. Food Manufacturing Code.
RequirementWhat it asksClause
Proof it worksConfirmation that freezing, chilling and cold storage perform as they should11.6.2.1
CapacityEnough refrigeration for the most product you expect, with time allowed for cleaning11.6.2.2
A written procedureHow you monitor temperatures, how often you check, and what you do if a reading is out of specification11.6.2.3
Where the monitor goesTemperature monitoring equipment placed to monitor the warmest part of the room11.6.2.3
A displayA temperature display that is easy to read and easy to get to11.6.2.3
RecordsRecords of frozen, cold and chilled storage room temperatures11.6.2.3
CalibrationDocumented methods and responsibility for calibrating the equipment used for monitoring11.2.3

The warmest part of the room is found, not guessed

A cold room is not one temperature. It is warmer near the door, high up, and wherever the air cannot reach. The monitor has to sit at the warmest spot, so you need to know where that is.

A temperature mapping study finds it. You place loggers through the room for a set time and read where it runs warm. See temperature mapping for food cold storage, and where to put a sensor in a walk-in for a smaller box.

What a good SQF record looks like

SQFI's own guidance on records spells out what an auditor expects:

A reading that was out of range needs its corrective action written beside it: what went wrong, what you did, and what happened to the product. See automated logs and corrective actions for one filled in.

How long to keep SQF records

SQF sets no fixed period. A customer, a law or your insurer may set one. Otherwise, SQFI's guidance says to keep records for the commercial shelf life of the product. For short shelf-life products, keep them until after your next recertification audit, at least.

If FDA's preventive controls rule also applies to you, its 2 years is the longer rule for most chilled food. More in how long to keep temperature logs.

What the auditor will look at

SQFI lists what an auditor can check on records, in three ways:

Edition 10: what changes, and when

SQFI published Edition 10 in March 2026. Audits switch to it from 2 January 2027, if GFSI's review finishes on time. An audit before that date uses Edition 9. A surveillance audit after that date, from an Edition 9 audit, still uses Edition 9.

Edition 10 may number its clauses differently. Before your first Edition 10 audit, find where the cold storage and records clauses sit in the new Code.

Where TemperatureWise fits, and what stays yours

SQF's cold room requirements, what TemperatureWise covers, and what your team still does.
SQF asks forTemperatureWiseStill yours
Monitoring at the warmest part of the roomA wireless sensor at the spot your mapping found, read every 15 minutesFinding the spot. A mapping study does it
Action when a reading is outAlerts by email, then text and phone call, until someone answers. The corrective action is noted in the app beside the readingsWriting the procedure, and doing what it says
Records of room temperaturesEvery reading kept indefinitely, and exported as a spreadsheet fileReviewing the records, and signing the review
A display that is easy to readThe reading in the app, on any phoneThe room's own thermometer by the door, for anyone without the app
CalibrationNIST-traceable calibration certificates, quoted on requestYour calibration schedule

The full specification, from accuracy to encryption, is on TemperatureWise for IT and procurement.

The free cold room temperature records audit checklist below puts SQF, BRCGS and FDA side by side on one page, with a checklist to run before the audit.

Common questions

What are the SQF requirements for cold room temperature monitoring?

Clause 11.6.2 of the Food Manufacturing Code, Edition 9, asks for a written procedure for monitoring temperatures, with how often you check and what you do if a reading is out of specification. Monitoring equipment goes at the warmest part of each room, with a display that is easy to read, and you keep records of the room temperatures.

Check the wording against your own copy of the Code.

Where should a temperature monitor go under SQF?

At the warmest part of the room. A temperature mapping study shows where that is, because it changes with the door, the racking and the airflow.

How long must SQF records be kept?

SQF sets no fixed period. Keep them as long as a customer, law or insurer requires. Otherwise, SQFI's guidance says the product's commercial shelf life, and for short shelf-life products until after the next recertification audit, at least.

Are electronic temperature records acceptable for SQF?

Yes. SQFI's guidance allows electronic records, as long as they are secure and there are electronic signatures for whoever checks and whoever reviews.

When does SQF Edition 10 start?

Audits switch to Edition 10 from 2 January 2027, if GFSI's benchmarking review finishes on time. Audits before then use Edition 9.

Want the records kept for you

TemperatureWise reads every cold room every 15 minutes, keeps every reading, and calls until someone answers when one goes wrong.

Talk with us

Vimal Bhaya, Founder and Lead Systems Architect, Renergy Technologies.