A short guide

SQF, BRCGS and FDA: what each asks of your temperature records

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026

SQF and BRCGS are certificates your buyers ask for. FDA's preventive controls rule, 21 CFR Part 117, is a law for facilities that must register with FDA. Many sites face two of them at once.

Each part covers one: who it applies to, how it wants cold rooms monitored, what a record must hold, who reviews it and how long it is kept. The free audit checklist puts all three side by side.

The 3 parts, in order

By the end you will know which standard applies to you, where the monitor goes, what alarms or checks each one expects, what a reviewer signs, and how long to keep the records.

  1. 1. SQF temperature monitoring and record requirements

    A monitor at the warmest part of each room, a written procedure, and every record signed by whoever took it and whoever reviewed it. Edition 9's clauses, and when Edition 10 takes over.

    Read part 1
  2. 2. BRCGS temperature monitoring and record requirements

    Alarms on every store, or a recorded check every 4 hours through nights and weekends. Validated cold stores, calibration, and records kept for shelf life plus 12 months.

    Read part 2
  3. 3. 21 CFR 117: temperature monitoring and records

    Monitoring often enough to show it works, exception records for refrigeration, a review within 7 working days, and 2 years' retention. The shorter rule for cold stores, 117.206.

    Read part 3

How to use this

Read them in order if you are starting from scratch. That is the usual path. If you already know which piece you need, jump to it from the list above.

Common questions

Which food safety standard asks most of temperature records?

It depends on the row. BRCGS asks for alarms on every store or a check every 4 hours, and records kept for shelf life plus 12 months. FDA's preventive controls rule asks for a review within 7 working days and 2 years' retention. SQF asks for the monitor at the warmest part of each room. A site under more than one meets the strictest line in each.

Do SQF and BRCGS apply to restaurants?

They are certificates a business chooses, usually because a buyer asks, so they are most common in food plants and warehouses. FDA's preventive controls rule does not apply to restaurants or retail stores, which follow their state's food code.

Are electronic temperature records acceptable?

Yes, under all three. SQF wants electronic signatures for whoever checks and reviews, BRCGS wants them stored securely and backed up, and FDA's preventive controls rule exempts them from Part 11.

Want the records kept for you

TemperatureWise reads every cold room every 15 minutes, keeps every reading, and calls until someone answers when one goes wrong.

Talk with us