BRCGS temperature monitoring and record requirements
By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026
This is a continuation of Food safety standards and temperature records, a 3-part tutorial. You are on part 2 of 3.
BRCGS Food Safety Issue 9 gives you a choice for each cold store. Fit a recorder with alarms. Or check it by hand and write it down, typically at least every 4 hours. Either way, you must be able to act before the food passes its limits.
Freezers and cold stores also need the spread of temperature proved. Records are kept for at least the shelf life of the food plus 12 months.
BRCGS is a certificate your buyers ask for, not a law
BRCGS Food Safety is a certificate. Sites get it because a buyer asks, very often a big retailer. It is one of the schemes GFSI recognises, so many buyers take it in place of SQF.
This page covers the Food Safety standard, Issue 9. That is the issue audits use today. Warehouses have a separate BRCGS standard for storage and distribution. If FDA's rules apply to you too, see 21 CFR 117 temperature records.
Alarms on every store, or a check by hand every 4 hours
Clause 4.15.3 decides how you watch a cold store. The store must hold the food within its limits. Then you prove it in one of two ways:
- A recorder with alarms in every store.
- Checks by hand that are written down, "typically on at least a 4-hourly basis". They must come often enough to act before the food passes its limits.
As practitioners quote BRCGS's guide to the clause, checks by hand go on through nights and weekends too. That is 6 checks a day, or 42 a week, for each store. So most sites fit recorders with alarms.
Prove how the cold spreads through freezers and cold stores
Clause 6.1.5 covers kit that is key to safe food. For freezers and cold stores, the spread of temperature has to be proved. It is then checked again, as often as the risk calls for.
In practice that is a mapping study. You put loggers all through the room. They show how even it is, and where it runs warm. Do it again after you change the racks or the cooling. See temperature mapping for food cold storage.
Calibration: a list, a due date and a traceable reference
Clause 6.4 covers the devices that check the temperature.
| Clause | What it asks |
|---|---|
| 6.4.1 | A documented list of the measuring equipment that monitors critical control points, with where each is, an identification code and a calibration due date |
| 6.4.2 | Each device checked, and adjusted where needed, at a frequency based on risk. Equipment readable, and accurate enough for its job |
| 6.4.3 | Reference equipment calibrated and traceable to a recognised national or international standard. The uncertainty of calibration considered against critical limits |
Records: clear, safe, and kept shelf life plus 12 months
Clause 3.3 sets the rules for every record:
- Easy to read, in good condition, and easy to find (3.3.1).
- Every change approved, with the reason written down (3.3.1).
- Electronic records kept safe, for example behind a password, and backed up so none are lost (3.3.1).
- Kept for a set time. It must allow for the law, your buyers and the shelf life. If the label lets the shopper freeze the food, count that longer life (3.3.2).
- At least the shelf life plus 12 months (3.3.2).
How long other rules keep records is in how long to keep temperature logs.
Issue 10 is being written. Issue 9 still applies
Issue 9 came out in August 2022. Sites are still audited to it. BRCGS updated its position statements for audits from 10 August 2026. For Food Safety, the one new clause change was about protective clothing. Issue 10 is being written, and is not out yet.
Where TemperatureWise fits, and what stays yours
| BRCGS asks for | TemperatureWise | Still yours |
|---|---|---|
| Recording equipment with alarms on every store (4.15.3) | A wireless sensor in every store, read every 15 minutes, with alerts by email, then text and phone call, until someone answers | Setting the limits for each product |
| Action before product passes its limits | Alerts within hours of a stop, and most failures flagged days ahead from a change in the room's pattern | Acting on the alert, and recording what you did |
| Temperature distribution validated (6.1.5) | A mapping study, sold separately, that finds where each room runs warm | Repeating it after layout or refrigeration changes |
| Calibration (6.4) | NIST-traceable calibration certificates, quoted on request | Your device list and due dates |
| Records kept securely, at least shelf life plus 12 months (3.3) | Every reading kept indefinitely, with corrective actions beside them, exported as a spreadsheet file | Your retention period, and reviewing the records |
Every spec, from accuracy to encryption, is on TemperatureWise for IT and procurement.
The free audit checklist below puts SQF, BRCGS and FDA side by side. It ends with a list of checks to run before the audit.