21 CFR 117: temperature monitoring and records under FDA's preventive controls rule
By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026
This is a continuation of Food safety standards and temperature records, a 3-part tutorial. You are on part 3 of 3.
If your site must register with FDA, Part 117 applies. Where cooling is one of your preventive controls, you check it often enough to show it works. The records are reviewed within 7 working days and kept for 2 years.
For cold storage, the records can be exception records, which show only when control was lost. Restaurants and food stores are not covered.
Who Part 117 applies to
Part 117 is FDA's preventive controls rule for human food. In general, it applies to sites that must register with FDA. Those are sites that make, process, pack or hold food. Farms, restaurants and food stores do not register. So this part of the rule does not apply to them.
Some sites, such as very small firms, get exemptions or a lighter rule. A site that only stores packed food that must be kept cold has its own short rule, 117.206. It is covered below. If you also hold a certificate, see SQF or BRCGS temperature records.
Checks: written down, and often enough to show it works
Where cooling is a preventive control, 117.145 asks for two things:
- Written steps for the checks, including how often they are done.
- Checks "with adequate frequency", to show the control works every time.
The rule sets no fixed gap between checks. It has to be often enough to show the room held, every day. That includes nights and weekends.
For cold storage, exception records are allowed
Under 117.145(c), the records for cold storage can be either kind:
- Affirmative records, which show each reading was in range.
- Exception records, which show only the times control was lost.
A system that keeps every reading gives you both. You have the full record, and each loss of control picked out of it.
When the cold is lost
When a room loses its temperature, 117.150 calls for a corrective action. You find and fix the problem. You make it less likely to happen again. You check the food that was in it for safety.
Where needed, you keep that food out of commerce. And you write all of it down. See automated logs and corrective actions for a record that covers each point.
Checks on the checks: calibration, and a review within 7 working days
117.165 makes sure the checks themselves work.
| Check | What the rule asks |
|---|---|
| Calibration | Calibrate the instruments that monitor, or check them for accuracy (117.165(a)(1)) |
| Records review | Monitoring and corrective action records reviewed within 7 working days after they are created, or longer with a written reason from the preventive controls qualified individual (117.165(a)(4)(i)) |
What every record has to hold
117.305 sets the rules for every record under Part 117. Each record must:
- Be the original, a true copy, or an electronic record.
- Hold the real values from each check.
- Be accurate, hard to erase, and easy to read.
- Be made at the time of the check.
- Give enough detail to show what was done.
- Name the site, and carry the date, the time where it matters, and the initials or signature of the person who did it.
Electronic records kept for Part 117 do not have to meet Part 11, FDA's rule for electronic records (117.305(g)).
Keep them 2 years, and hand them over when asked
- Keep each record at least 2 years from the day it was made (117.315).
- You can store them off site if you can bring them back within 24 hours of a request. Electronic records count as on site if you can reach them from the site.
- Hand them to FDA promptly when it asks to review or copy them (117.320).
Cold stores that only hold packed food: 117.206
A site that only stores sealed, packed food that must be kept cold has a shorter rule. It still has to:
- Set temperature controls that stop germs that cause illness from growing.
- Check them often enough to show they work every time.
- Act when control is lost. Fix it, make a repeat less likely, check the food, and keep unsafe food out of commerce.
- Verify. Calibrate the devices or check their accuracy. Review the calibration records. Review the check and corrective action records within 7 working days.
- Keep records of the checks, the corrective actions and the verification. Exception records are allowed.
More for that kind of site on temperature monitoring for cold storage.
Where TemperatureWise fits, and what stays yours
| Part 117 asks for | TemperatureWise | Still yours |
|---|---|---|
| Monitoring with adequate frequency (117.145) | Every room read every 15 minutes, nights and weekends included | Writing the monitoring procedure |
| Records with actual values, date and time (117.305) | Every reading time-stamped and kept indefinitely, exported as a spreadsheet file | Naming who is responsible for each room |
| Corrective actions documented (117.150) | Alerts by email, then text and phone call, until someone answers. The corrective action is noted in the app beside the readings | Evaluating the food, and deciding what happens to it |
| Review within 7 working days (117.165) | Every reading and every excursion in one place, ready to review | The review itself, and its record |
| Calibration (117.165) | NIST-traceable calibration certificates, quoted on request | Your calibration schedule |
| Kept 2 years, produced on request (117.315) | Kept indefinitely, reachable from any site with internet | Your retention policy |
Every spec, from accuracy to encryption, is on TemperatureWise for IT and procurement.
The free audit checklist below puts SQF, BRCGS and FDA side by side. It ends with a list of checks to run before the audit.