Renting mobile refrigeration while your walk-in is repaired
By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026
This is a continuation of When a walk-in fails, a 3-part tutorial. You are on part 2 of 3.
Rent when the repair will take longer than your food can wait. A small refrigerated trailer rents for about $175 to $330 a day, and a refrigerated container for about $1,000 to $3,000 a month. That is usually far less than a walk-in full of stock.
Three things decide whether it works: finding a unit free in time, having the power to run it, and loading food that is already cold. These units are built to hold food cold, not to chill warm food down.
Rent when the repair will outlast the food
Most walk-in repairs are done in a day. A rental earns its cost when the fix will take longer than the food can wait:
- A part on order, such as a compressor or a coil, with days before it arrives.
- No technician free. One operator summed it up in a post we found in our own research: "My refrigeration guy isn't available until Tuesday. It's at 34 degrees."
- A planned repair that needs the box empty and warm for a few days.
- Nowhere else on site with room for the stock.
The best rental is the one you book before the box fails. At a Philadelphia site we watch, a freezer gave nearly 30 days of warning. Before the final repair, the team moved $450,000 of frozen stock into a temporary reefer, and the repair ran from 24 to 27 July 2025 as planned work. The full story is in the dual-system freezer case study.
Three kinds of rental, and what each one needs
| Unit | Power it needs | Published price |
|---|---|---|
| Small cold-storage trailer, from about 5 by 10 feet to 7 by 16 feet. A 5 by 10 fits in a parking spot | A normal 110 to 120 volt, 20 amp circuit for the small ones | About $175 to $330 a day, $735 to $1,295 a week, or $1,900 to $3,500 a month |
| Refrigerated container, 20 or 40 feet, set on a level spot | Usually 460 volt three-phase on a 30 amp circuit. Some 20 foot units run on 220 volt single-phase, 50 amp. A normal wall outlet will not run one | About $1,000 to $3,000 a month, often billed in 30-day cycles |
| Reefer trailer, up to 53 feet, with its own refrigeration unit | Its own diesel engine, or shore power where the unit has electric standby, for example 460 volt three-phase, 30 amp | Ask for a quote, and add fuel |
| Generator, if there is no power to plug into | Diesel, about 4 to 8 gallons a day | About $50 to $150 a day on top of the unit |
Set the price against what is in the box. If the stock is worth more than the rent for the days of the repair, renting is the cheaper loss.
If you need it for frozen food, ask for the lowest temperature the unit holds when loaded. Containers commonly hold from -22°F to 86°F (-30°C to 30°C). Not every small trailer is built to hold frozen food.
Before it arrives: power, place and permission
- Have an electrician check your power before delivery: the voltage, the amps and whether it is single-phase or three-phase. A unit that cannot be plugged in is a very expensive box.
- Pick a level spot near the kitchen door, where the delivery truck can reach and staff can carry food in a few minutes.
- Plan for a generator only outdoors. Never run one indoors or in a garage, and keep it at least 20 feet from doors, windows and vents. Its exhaust carries carbon monoxide.
- Plan the move: who carries the food, with what, and how the unit is locked at night.
- Ask your health department whether it needs to know about the unit, or see it. The food in it is still your food, under the same rules as your own walk-in.
Cool it first, then load food that is already cold
A rented unit holds food cold. It does not chill warm food. Carrier says in its trailer manual that its unit was not designed to cool warm product, only to keep product at the temperature it was loaded. Treat any rented unit the same way.
- Pre-cool it empty. Thermo King asks for at least 30 to 60 minutes, longer if possible. USDA says it can take 2 hours or more in hot weather.
- Load only food at 41°F (5°C) or colder, or frozen food at 0°F (-18°C) or colder. Food that is already warm stays warm. Decide about it first, as in the first four hours.
- Leave room for the air. Keep a gap above the load and along the walls, and do not block the unit's air return. The makers' figures are in how a reefer unit works.
- Put a thermometer inside that you can read without opening the door, and log it like your own walk-in.
- Keep the door shut. Plan trips so each opening is short.
The hard part is finding one free, so line it up now
A rental is only an option if a unit is free the day you need it. Health department emergency plans say to find your sources of dry ice, generators and refrigerated trucks ahead of time. Do it on a quiet day:
- Find two rental companies that deliver to you. Some refrigeration contractors rent trailers themselves, so ask yours.
- Write down what size you would need, the power each unit needs, and whether your site has it.
- Put both numbers in your emergency plan, on paper, with your contractor, insurer and health department.
Keep the receipt: it belongs in the claim
Money you spend to save the rest of the stock, such as a rented trailer or dry ice, is part of the loss. Insurance guides list those receipts among the records to keep. Whether your policy pays for them depends on its wording, so ask your broker. See how to build a spoilage inventory an adjuster will accept.
TemperatureWise gives you the days to plan the rental
Most failures show days ahead as a change in the box's pattern. TemperatureWise reads every box every 5 minutes and flags that change. That is the warning that let the Philadelphia team book a temporary reefer and move $450,000 of stock before the repair, not after.
A rented unit needs watching too. A wireless sensor can go into it for as long as you have it, if it is within range of your site's gateway. Alerts go by email, then text and phone call, until someone answers.