Documenting a food loss for the health department
By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 16 November 2026
This is a continuation of When a walk-in fails, a 3-part tutorial. You are on part 3 of 3.
Write down five things: when it started, the temperatures you took, what you threw out and why, how it left the site, and what fixed the unit. Health departments and insurers may both ask for the type and amount of food thrown out. Insurers also want costs.
Write it while it happens. A record made at the time, with times and initials, is the one that answers questions later.
Who asks for the record, and what they look for
- The health department wants to know the food you kept was safe to keep, and the food you threw out really went. Emergency guidance says "the Regulatory Authority and/or insurance companies may request" a record of the type and amount of food discarded.
- The inspector at your next visit may ask how a failure was handled. A record written at the time shows it.
- Your insurer wants the same list, with quantities, costs and the cause. See how to build a spoilage inventory an adjuster will accept.
The food decision is the part the health department cares about most. Food with no record of its time and temperature is treated as unsafe. So the records you keep during a failure decide how much food you can keep.
Five records cover a food loss
| Record | What to write | What it proves |
|---|---|---|
| 1. The timeline | When the failure was found, when it started if known, when the technician came, when the box was fixed and when food went back in | How long the food was at risk. The 4-hour clock runs from it |
| 2. The temperature log | Box and food readings, each with the date, time, item, where it was and who took it | Which food was safe to keep |
| 3. The discard log | Each item thrown out, how much, the reason, and initials | The type and amount of food thrown out |
| 4. The disposal record | How it left the site, and the waste company's receipt | That the food did not end up sold or served |
| 5. The cause and the fix | The technician's report, the cleaning of the box, and the reading that showed it was holding again | That the problem is fixed and the box is safe to use |
During the failure, log the food, not just the box
Emergency guidance says the temperatures of TCS food "must be recorded" during an outage. Its sample logs show where the food was, the date, the time, the temperature and what was done with it. TCS food is food that needs time and temperature control to stay safe, such as meat, fish, dairy and cooked food.
- Start with the time you found the failure, and the box's own thermometer reading.
- Probe the food in several places, and write down each reading.
- Check again at set times until every item is decided.
- Write the decision beside each reading: kept, moved, cooked or thrown out.
A discard log, line by line
Health departments publish simple discard logs. Bethlehem, Pennsylvania's has the date and time, the food item, the reason, whether it was damaged or discarded, notes, the employee's initials and a manager's check. Here is the same layout, filled in as an example:
| Date and time | Food item | Amount | Reason | Initials | Checked by |
|---|---|---|---|---|---|
| 16 Nov, 7:40 AM | Raw chicken thighs | 3 cases, 120 lb | Walk-in 2 found at 52°F (11°C) at opening. Time above 41°F (5°C) unknown | AB | CD |
| 16 Nov, 7:45 AM | Shredded cheese | 6 bags, 30 lb | Same failure. Food read 48°F (9°C) | AB | CD |
| 16 Nov, 7:50 AM | Cooked rice, in pans | 4 pans | Same failure. Cooked food, time unknown | AB | CD |
Use the name on the supplier's invoice for each item. The same lines then serve the insurer, who needs quantities and costs.
Throw it out properly, and keep proof it went
- Keep it apart from other food, in covered bins, and label anything you hold "Not for sale".
- Photograph it before it goes, and tell your insurer before you throw it out, if you can.
- Use your waste company, and follow your state and local rules. For a large load, call the landfill before you send it.
- Keep the receipt with the discard log.
Close it out as a corrective action
A good record does not stop at the bin. It says what went wrong and why, what fixed it, what stops it happening again and what happened to the food. That is a corrective-action record, and automated logs and corrective actions shows one filled in for a real night.
For the box itself, keep the technician's report, and note that you washed and sanitized it once the food was out. Write down the reading that showed it was back at 41°F (5°C) or colder, or 0°F (-18°C) for a freezer, before you restocked it.
When the health department needs a call, not just a record
Most losses need a record on file, not a phone call. Two cases need the call:
- You cannot keep food safe. Under the FDA Food Code, a business stops operating and tells the health department when an imminent health hazard may exist, such as an extended loss of power. Wisconsin's guidance says to stop at once if you cannot operate safely.
- You were closed. A business that was ordered to close reopens only when the health department allows it.
Some health departments approve an emergency plan in advance, and that plan can let you keep operating through an outage. If you are not sure whether to call, call. How long to keep the records afterwards depends on your local rule. See how long to keep temperature logs.
TemperatureWise keeps the hours nobody was there
The record that is hardest to make by hand covers the night nobody was in. TemperatureWise records every cooler and freezer every 5 minutes, so it shows when a box started to warm and when the air passed 41°F (5°C).
Whoever answers the alert can note the corrective action in the app, beside the readings. The readings can be exported as a file to hand to an inspector or an insurer, like the week of reefer readings in our saves log. Pair it with your probe readings: the air warms before the food, and the inspector cares about the food.