Temperature log basics

How to do temperature logs correctly

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 21 October 2026

This is part 1 of 4 in Temperature log basics, a short tutorial on keeping temperature logs that hold up.

Take a real reading with a thermometer you have checked, in the warmest part of the box. Write it down straight away, with the time, the unit, your initials and what you did if it was out of range. Then make sure someone reads the log every day.

Under the FDA Food Code, cold food has to stay at 41°F (5°C) or colder and hot food at 135°F (57°C) or hotter. A log is the record that shows it did, between one inspection and the next. It only works if every number in it was actually read.

Every entry needs seven things

A log is a list of entries. Each one has to stand on its own, so that someone reading it a year later knows what was checked, when, by whom, and what happened next.

The seven parts of a temperature log entry.
PartWhat to writeWhy it matters
DateThe day of the checkLogs get filed, and pulled out months later
TimeThe time you took the reading, not the time slot printed on the formA 3 PM check done at 4:10 PM says so
UnitWhich cooler, freezer or hot holding unitOne sheet usually covers several boxes
ReadingThe number on the thermometer, with °F or °CNot rounded, and never the target printed on the form
InitialsOf the person who took the readingWhoever wrote it can be asked about it
ActionWhat you did, if the reading was out of rangeA high reading with nothing beside it looks ignored
Checked byInitials of the person who read the log that dayShows that someone looked

The Food Code sets the temperatures, not the layout of the sheet. The layout above follows what federal rules ask of food plant records: the actual value, the date and time, and the initials of the person who did the check, written when it was done (21 CFR 117.305). A state school log asks for the same: "the date, time, air temperature, corrective action, and initials", with the manager reviewing it "each working day".

Check the thermometer before you trust it

A log is only as good as the thermometer behind it. The Food Code requires food thermometers to be accurate to within 2°F, or 1°C on a Celsius scale (4-203.11). The ice-water check takes two minutes:

  1. Fill a glass with ice, then top it up with cold water. Stir, and let it sit for a minute.
  2. Put the probe in the middle of the glass, not touching the sides or the bottom, and wait for the number to settle.
  3. Should read: 32°F (0°C). If it is off, adjust it if it has a calibration nut or button. If it cannot be adjusted, replace it.
  4. Write the check down, with the date, the reading and your initials.

A thermometer that has been dropped gets checked again before it is used. How electronic sensors drift, and what actually spoils them, is in sensor accuracy, drift and calibration.

Measure in the warmest part of the box

The Food Code says the thermometer in a fridge or freezer goes in "the warmest part" of the unit (4-204.112). School kitchen guidance says the same for checking a cold holding unit by hand.

Air changes faster than food. A door left open warms the air in minutes, while a full tray takes far longer. If the air reads high, probe the food before you decide anything. Glycol buffers and thermobuffers shows the difference on real readings.

Write it down when you take it, and write what you saw

A reading out of range needs an action written next to it

When cold food or a cold box reads above 41°F (5°C), school kitchen guidance from the Institute of Child Nutrition sets out what to do:

  1. Probe the food in its thickest part, to see whether the food is warm or only the air.
  2. Chill it fast if it was fine 2 hours ago. If the last reading at or below 41°F (5°C) was within the last 2 hours, rapidly chill the food: a blast chiller, an ice water bath, or smaller, thinner portions.
  3. Throw it out if you cannot tell how long. Food goes in the bin if nobody can say how long it was above 41°F (5°C).
  4. Fix or reset the box before food goes back in.
  5. Write down what you did, next to the reading.

Do not put food back into a box that has not come back to 41°F (5°C) or colder.

If the box itself is the problem, walk-in cooler troubleshooting and reach-in cooler troubleshooting go through the causes one at a time.

Someone has to read the log every day

The Food Code makes the person in charge responsible for "daily oversight of the employees' routine monitoring of food temperatures" (2-103.11). In practice, that means reading the log before the shift ends:

Who does each part is set out in who is responsible for temperature logs, and how long to keep the sheets afterwards in how long to keep temperature logs.

TemperatureWise records the hours between the rounds

A log taken by hand is a few snapshots a day. TemperatureWise records each box at least every 15 minutes, day and night, and keeps the record indefinitely. When a box drifts out of its normal pattern, it emails, then texts and calls until someone answers.

It does not replace the people. Staff still check thermometers, still probe food when they cook, cool and receive it, and still write down what they did about a high reading.

Common questions

What should be on a temperature log?

Seven things for each entry: the date, the time of the reading, which unit, the reading with °F or °C, the initials of the person who took it, any action taken, and the initials of the person who read the log that day.

That follows what federal rules ask of food plant records: the actual value, written when the check was done, with the date, time and initials.

What temperature should a fridge be on a temperature log?

41°F (5°C) or colder, under the FDA Food Code. Most reach-in coolers are set lower, usually 35°F to 38°F (2°C to 3°C), so that door openings do not push the air past the line.

Hot holding is the other way round: 135°F (57°C) or hotter.

Do I log the air temperature or the food temperature?

Both, for different jobs. Log the air in the warmest part of the fridge or freezer for the box, and probe the thickest part of the food when you check food that is being held, cooled or received.

If the air reads high, probe the food before deciding anything. Air warms in minutes when a door opens, and a full tray takes far longer.

What do I do if a reading on the temperature log is too high?

Probe the food, act, and write down what you did. If cold food is above 41°F (5°C) but read 41°F or colder within the last 2 hours, chill it fast. If you cannot tell how long it has been warm, throw it out.

Fix or reset the box before food goes back in, and write the action next to the reading.

Can I fill in a temperature log at the end of the shift?

No. Each reading should be written when it is taken. Federal rules for food plants ask for records created at the time of the check, and a whole day written at once is what the trade calls pencil whipping.

If a check was missed, leave the box blank and write why.

Want the readings between rounds

TemperatureWise records every cooler and freezer at least every 15 minutes and keeps the record indefinitely. Your staff keep the judgment calls, not the clipboard.

Talk with us

Vimal Bhaya, Founder and Lead Systems Architect, Renergy Technologies.
He spent about a decade designing the analog circuits inside enterprise server chips at Oracle, from high-speed data links to DDR4 memory systems. He now designs the sensors and the detection models behind TemperatureWise.
Sources
  • Cold holding at 41°F (5°C) or colder and hot holding at 135°F (57°C) or hotter, 3-501.16: FDA Food Code 2022
  • Records with "the actual values and observations obtained during monitoring", "accurate, indelible, and legible", "created concurrently with performance of the activity documented", with the date, time and initials: 21 CFR 117.305
  • A state school refrigeration log asking for "the date, time, air temperature, corrective action, and initials", reviewed by the manager "each working day": Nebraska Department of Education, refrigeration log
  • Food thermometers accurate to plus or minus 2°F, or 1°C on a Celsius or dual scale, Food Code 4-203.11, as adopted in Minnesota Rules 4626.0555
  • The thermometer in "the warmest part of a mechanically refrigerated unit", Food Code 4-204.112, as adopted in Minnesota Rules 4626.0620
  • Check cold holding units with a thermometer "in the warmest part of the holding unit"; probe food in its thickest part; chill rapidly only if the last reading at or below 41°F was within 2 hours; "Discard food if it cannot be determined how long the food temperature was above 41 °F"; record corrective actions: Institute of Child Nutrition, Holding Cold Foods
  • The person in charge's "daily oversight of the employees' routine monitoring of food temperatures", and the duties for cooling, receiving and training, Food Code 2-103.11, as adopted in Minnesota Rules 4626.0035
  • Reach-in cooler settings, usually 35°F to 38°F (2°C to 3°C), from the makers' manuals: how a reach-in cooler works

Last reviewed 21 October 2026.