What health inspectors actually look for

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 25 October 2026

This is a continuation of Temperature logs and inspections, an 8-part tutorial. You are on part 3 of 8.

Inspectors spend most of their time on the things that make people sick. On the FDA's model report, items 1 to 29 are these risk factors. Seven of them are about time and temperature: cooking, reheating, cooling, hot and cold holding, date marks, and time used in place of temperature.

For coolers, the inspector puts a thermometer in your food, then reads your log to see whether that number is normal for you. Cold holding is the item US restaurants miss most: FDA found it out of compliance at least once in 62% of fast food and 80% of full-service restaurants.

The FDA inspection report has two halves: risk factors and good retail practices

Many states use the FDA's model inspection report, or one close to it. It has 55 items. Items 1 to 29 are the foodborne illness risk factors: the things that make people sick. Items 30 to 55 are good retail practices: cleaning, storage, equipment and the building.

Each violation also carries a tag, priority, priority foundation or core, that sets how fast it has to be fixed. The tags are explained further down.

Seven of the risk-factor items are about time and temperature

Temperature-related items on the FDA model inspection report, 2022 Food Code.
ItemWhat the inspector checks
1Person in charge present, demonstrates knowledge, and performs duties
2Certified food protection manager
18Proper cooking time and temperatures
19Proper reheating procedures for hot holding
20Proper cooling time and temperatures
21Proper hot holding temperatures
22Proper cold holding temperatures
23Proper date marking and disposition
24Time as a public health control: procedures and records
36Thermometers provided and accurate (a good retail practice)

Cold holding is the item US restaurants miss most often

FDA sent trained staff into hundreds of US restaurants in 2017 and 2018. Cold holding was out of compliance at least once in most of them.

Share of US restaurants where FDA found each item out of compliance at least once, 2017 to 2018.
ItemFast foodFull-service
Cold holding, TCS food at 41°F (5°C) or colder62.2%79.8%
Hot holding, TCS food at 135°F (57°C) or hotter18.5%26.3%

In full-service restaurants, no item in the whole study was missed more often. In fast food it came second. FDA also found that kitchens with a food safety system in place, meaning written steps, training and checks, kept the risk factors under control best.

The inspector measures the food, not just the air

The inspector's guide for item 22 says cold holding is marked on real food temperatures, taken with a checked thermometer. The inspector also asks the person in charge whether a food is cooling, held on time instead of temperature, or not TCS food at all.

One TCS food out of temperature can put the item out. So the number on the cooler display is not the answer. The food is. See cold holding, hot holding and the danger zone.

The person in charge has to answer questions about temperatures

Item 1 checks that the person in charge knows the job. They can show it three ways: no priority violations on the day, a food protection manager certificate, or right answers to the inspector's questions.

The Food Code lists what those questions cover. One of them is the times and temperatures for cold storage, hot holding, cooling and reheating. The numbers to know are in preparing for a health inspection.

A temperature log is read for patterns, not for one number

The Food Code gives the inspector access to your records. When they read a temperature log, these are the questions it answers:

Here is what a bad log looks like. These number strips come from a real kitchen's paper log. Read for patterns, they look written to fill the boxes, not taken at the times shown.

Number strips cut from one kitchen's daily temperature log sheets, under our own column labels for checks at 3, 7 and 11 AM and 3, 7 and 11 PM. On Saturday an undercounter fridge reads 38, 37, 38 in the morning and 38, 37, 38 again in the evening. A reach-in freezer reads about minus 18 at every check but one on Saturday, Sunday and Tuesday, under a label that reads 0 Fahrenheit, minus 18 Celsius. Every reading on the six sheets is in range, with no comment or action written beside any of them.

The full story of this log, and the signs to look for in your own, is in pencil whipping.

One restaurant worker said what their health department cares about most, after overall temperature:

"Warm food needs to be cooled to under 40F in a certain time. Can you provide equipment that shows that has occurred? This is the main concern [after overall temperature] for my health department."

r/KitchenConfidential

Priority, priority foundation and core come from the Food Code, not from the inspector

Every violation on the report is tagged by how directly it can make someone sick. The tag is not the inspector's opinion. Each paragraph of the Food Code carries its tag in the code itself: P for priority, Pf for priority foundation, and no mark for core. The inspector writes down the rule you broke, and its tag comes with it.

Some states print the tags on the form. Texas's report lists priority items first, as items 1 to 20, then priority foundation items 21 to 33, then core items from 34. On it, cold holding is a priority item, and an accurate food thermometer, or a thermometer in the warmest part of each cooler, is a priority foundation item.

Other places use their own names for the same idea. New York City has public health hazards, critical and general violations. Santa Clara County, California, has major and minor violations. All the names are side by side in critical vs minor infractions, and what happens when they are not fixed is in preparing for a health inspection.

Priority items are fixed on the spot or within 72 hours

Under the model Food Code, as Virginia adopted it, priority and priority foundation items are corrected at the time of the inspection. If that is not possible, priority items get up to 72 hours and priority foundation items up to 10 calendar days. Core items get up to 90 calendar days.

The inspector leaves a copy of the report. How often they come depends on where you are. The model Food Code says at least once every 6 months, with longer gaps allowed on a risk-based plan. Cincinnati, for example, inspects at least once a year, without warning. It says the inspector "may visit anytime the restaurant is operating."

Want a log that always matches what the inspector finds?

TemperatureWise prints your daily cooler and freezer log for you. Each box gets a daily sheet with the reading at each check time, the highest reading since the last check, and the time spent above 41°F (5°C). It is filled from readings taken at least every 15 minutes, day and night, so nobody has to remember the check and nobody can make up a number.

The inspector will still probe the food. TemperatureWise measures the air where the sensor sits, or a glycol buffer bottle (an optional add-on) that tracks the food more closely. It does not cover cooking, cooling or hot holding.

Common questions

What do health inspectors look for in a restaurant?

The foodborne illness risk factors first: food held at the wrong temperature, cooking, cooling, reheating, handwashing and hygiene, safe sources and clean equipment. On the FDA's model report these are items 1 to 29 of 55. The rest cover cleaning, storage, equipment and the building.

What is a priority violation in a health inspection?

A violation of a rule that controls a hazard directly, such as cooking, reheating, cooling or handwashing. It is corrected during the inspection, or within 72 hours under the model Food Code.

How often are restaurants inspected?

At least once every 6 months under the model FDA Food Code, though many health departments set longer, risk-based intervals. Cincinnati, for example, inspects at least once a year, unannounced. Ask your health department for its schedule.

What is the most common health code violation?

Cold holding is one of the most common. In FDA's 2017-2018 study it was out of compliance at least once in 62.2% of fast food and 79.8% of full-service restaurants, the highest of any item in full-service.

Do health inspectors check temperature logs?

Yes, when the rules require records, and the Food Code gives them access to your records. They compare the log with the food temperatures they measure, and look for real times and an action next to any bad reading.

Does the inspector decide whether a violation is priority or core?

No. The tag comes from the Food Code itself: each rule is marked priority (P), priority foundation (Pf) or, if unmarked, core. The inspector records which rule was broken, and its tag follows.

Cold holding at 41°F (5°C) is a priority item. An accurate food thermometer is a priority foundation item.

Want a record that matches what the inspector finds

TemperatureWise keeps a reading from every cooler and freezer every 15 minutes. Show the inspector the night, not just the morning check.

Talk with us

Vimal Bhaya, Founder and Lead Systems Architect, Renergy Technologies.
He spent about a decade designing the analog circuits inside enterprise server chips at Oracle, from high-speed data links to DDR4 memory systems. He now designs the sensors and the detection models behind TemperatureWise.
Sources
  • Cold holding marked "based on actual food temperature measurements using a calibrated food temperature measuring device"; items 1, 2, 18 to 24 and 36; items 1 to 29 risk factors and 30 to 55 good retail practices: Guide 3-B, marking instructions for the FDA inspection report, 2022 Food Code, Connecticut DPH
  • Definitions of TCS food, priority, priority foundation and core items, Food Code 1-201.10, as adopted in 12VAC5-421-10
  • Cold holding out of compliance at least once in 62.2% of fast food and 79.8% of full-service restaurants, hot holding 18.5% and 26.3%: FDA, The occurrence of foodborne illness risk factors in fast food and full-service restaurants, 2017-2018, data items 5 and 6. "The two most commonly occurring risk factors were improper holding time and temperature, and poor personal hygiene": FDA's announcement of the report. Food safety management systems "were the strongest predictor that risk factors would be minimized": the same announcement
  • Questions on "the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating" of TCS food, Food Code 2-102.11, as adopted in Minnesota Rules 4626.0030. Three ways to show knowledge: no priority violations, a certified food protection manager, or correct answers to the inspector: Oregon Department of Agriculture, demonstration of knowledge
  • Records available to the inspector, Food Code 8-402.11, as adopted in Minnesota Rules 4626.1790
  • Quote: our own research into public discussions, in r/KitchenConfidential. The quoted lines are exact
  • Inspection at least once every 6 months, with longer risk-based intervals (Food Code 8-401.10); priority and priority foundation items corrected at the time of inspection, or within 72 hours and 10 calendar days; core items within 90 calendar days; a copy of the report at the end of the visit: Virginia's adoption, 12VAC5-421, Part VIII, Article 4
  • "An unannounced, onsite inspection at least once a year"; the inspector "may visit anytime the restaurant is operating": Cincinnati Health Department, food safety inspections and records
  • Priority, priority foundation and core: "A “P” or “Pf” designation after a (sub)paragraph indicates" the category, and "Any unmarked provisions within a section are Core items": Arizona Department of Health Services, Food Code changes overview
  • Report items 1 to 20 priority, 21 to 33 priority foundation, 34 onward core; cold holding (3-501.16) a priority item; food thermometers (4-203.11, 4-302.12) and the cooler thermometer at the warmest part (4-204.112) in item 29, priority foundation: Texas Department of State Health Services, inspection report code quick reference, August 2021
  • New York City violation categories, public health hazard, critical and general: NYC Health, How we score and grade
  • Santa Clara County placard color "based upon the total number of major violations observed during an inspection": County of Santa Clara, SCCDineOut

Last reviewed 25 October 2026.