How-to in SiteWise

How to turn your equipment spreadsheet into an asset list

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 24 November 2026

This is part 1 of 10 in How to do it in SiteWise, ten how-to guides, one maintenance job each, tap by tap.

Send the spreadsheet as it is to sitewise@renergytech.com, and the SiteWise team imports it for you, free, usually in 2 to 4 business days. Your machines come back as assets under their locations, ready to tag and put on PMs. To add a single machine yourself, open Assets and tap +.

The binder way means typing every machine twice

An equipment list usually starts as a walk around the site with a clipboard, and ends as a spreadsheet nobody else can find.

  1. Walk the site and copy each machine's name plate: make, model, serial number.
  2. Type it into the spreadsheet, with the room or the roof it sits on.
  3. Dig out the install dates and last service dates from old forms.
  4. Email the file to whoever needs it.
  5. Edit it again every time a machine is replaced.

Three checks show where it stops:

  1. Who else can see it: whoever has the latest copy.
  2. Can you prove anything: the list says a machine exists, not what was done to it.
  3. Does anything chase it: no, a row never reminds anyone of a PM.

Our import template has three tabs: locations, assets and work orders

Send your own spreadsheet as it is, or download our import template (Excel) and fill it in. Fill in Locations first: the Assets and Workorders tabs then offer your locations and assets in a dropdown. Green headers are the ones the import needs; the rest are optional.

Locations: one row per site, building or part of one.

Location nameAddressDescription
Building BUnit 4, 15 Example RoadTwo-story office building, plant on the roof

Assets: one row per machine. A part of a machine with its own record, such as the compressor in a rooftop unit, names its parent asset.

Asset nameLocationParent assetMake and modelSerial numberDevice typeEquipment categoryPlaced in service date
RTU 3Building BPackaged rooftop unit, 7.5 ton4519G20871Rooftop unitHVAC & Climate Control2019-03-12

Workorders: one row per asset, with up to five tasks, each with its frequency picked from a dropdown: Once, Daily, Weekly, Monthly or Yearly. Once is a one-off work order; the others become PMs. For now, a weekly, monthly or yearly task starts on the first day of that week, month or year.

AssetLocationTask1Task1FrequencyTask2Task2FrequencyTask3 to Task5
RTU 3Building BReplace return air filtersMonthlyCooling season checkYearlyEach with its own frequency

Each SiteWise asset also takes a photo, which you can add on the phone once it is imported.

The SiteWise way: send the file, or add one machine in five taps

By email, then on the phone

  1. Download the app free (opens in a new tab) and sign up.
  2. Email your spreadsheet as it is, or our template filled in, to sitewise@renergytech.com, from the address you signed up with. With your own file, add a line on what each column means if the headings are not clear.
  3. In 2 to 4 business days, open Assets. Each machine is there, under its location, with its category.
  1. Tap Locations to check the sites: each shows how many assets of each kind it holds, and its work orders and PMs.
  1. To add one machine yourself, go back to Assets and tap the blue +.
  2. Fill in Name, Serial Number and Model from the name plate, and add a photo of the plate.
  3. Set the Placed in Service Date, then pick the Location, the Device Type and the Device Category.
  4. Tap Add Asset.

* The phone screens show representative data, drawn from the app's design. Text in the real app is smaller, and a screen may differ slightly.

What you end up with is a list that does the work

Each asset sits under its location, with its category and a count of its work orders. Tag it with a QR code and anyone on site can open its record with one scan: see how to tag equipment with QR codes. Put it on a PM and SiteWise opens its work orders by itself: see how to set up a PM schedule.

New assets need a signal, so add them before the walk

Work orders and PMs can be created, updated and closed offline, on every plan. New assets and locations are added with a connection. Add a new machine from the office or the web, or on the phone once you are back in signal, and the technician on the roof works offline from there.

For one site with a handful of machines that one person looks after, a spreadsheet is good enough. It stops when more people need it than one file can serve.

Send us your spreadsheet

Sign up free, then email the file from the address you signed up with. The import is free on every plan, including the free plan, which holds 250 assets and sub-assets.

Common questions

Do we need to clean up the spreadsheet first?

No. Send it as it is. Add a short note on what each column means if the headings are not clear, and the SiteWise team sorts out the rest.

What columns should an equipment list have?

Name, location, type and install date are the core, with make and model and serial number if you have them. SiteWise's import template has them as three tabs: Locations, Assets, and Workorders with up to five tasks per asset, each with its frequency.

Is there a template for the equipment list?

Yes. Download the SiteWise import template (Excel), fill in its Locations, Assets and Workorders tabs, and email it to sitewise@renergytech.com. Dropdowns keep the locations, assets and frequencies consistent.

How long does the import take?

Usually 2 to 4 business days. The SiteWise team does it for you, free, on every plan, including the free plan.

How many assets does the SiteWise free plan hold?

250 assets and sub-assets combined, with 20 locations, unlimited work orders and 100 PMs. Premium has no limits.

Can a machine have parts with their own records?

Yes. A SiteWise asset can hold sub-assets, such as the compressor and the condenser fan inside one rooftop unit, and each keeps its own history.

Send us your equipment list

We import it free, so your team starts on real machines, not a blank app.

Moving off a spreadsheet? Send us your spreadsheet or export; we import it for you, free, usually in 2 to 4 business days. Email it to us

Download the app free

Download on the App StoreGet it on Google Play

Free on iPhone and Android.

Vimal Bhaya, Founder and Lead Systems Architect, Renergy Technologies.
He spent about a decade designing the analog circuits inside enterprise server chips at Oracle, from high-speed data links to DDR4 memory systems. He now designs the sensors and the detection models behind TemperatureWise.
Sources
  • The free import (send the spreadsheet as it is, usually 2 to 4 business days, free on every plan): From a maintenance spreadsheet to SiteWise
  • The import template, with its Locations, Assets and Workorders tabs and their dropdowns: SiteWise import template (Excel)
  • What each column becomes (assets, locations, PMs, parts): Switching to SiteWise
  • Offline: work orders and PMs are created, updated and closed offline on every plan; new assets and locations need a connection: SiteWise work order app
  • SiteWise plans and limits: unlimited work orders, 100 PMs, 20 locations, 250 assets, 250 parts, 100 tools and 25 vendors on the free plan, and no limit on users: SiteWise plans and pricing
  • The tap steps: the SiteWise app as designed, read 24 November 2026. The phone screens on this page are drawn with representative data

Last reviewed 24 November 2026.