SiteWise for chemical plants

Chemical plant maintenance software with a record for every inspection

SiteWise is a CMMS for chemical plants. It schedules the inspections and tests on pumps, valves, vessels, piping and relief devices, puts the checklist on the technician's phone, and keeps each work order with the version of the checklist it was done to. Parts for planned work are held 30 days ahead.

Download on the App StoreGet it on Google Play

Free on iPhone and Android.

Chemicals

What a plant team runs in SiteWise

  • Pump and seal inspections
  • Valve and relief device tests
  • Vessel and piping checks
  • Instrument and control checks
  • Eyewash and safety shower checks
  • Fire extinguisher checks

Free plan: unlimited work orders, no limit on users. See the limits

The equipment

The equipment a chemical plant keeps on a schedule

Pumps and seals

A PM for every pump

Seal checks, coupling alignment and lubrication, with the procedure linked so the steps travel with the job.

Valves and relief devices

Tests opened before they are due

Your engineers and the manufacturer set the intervals. SiteWise opens each test as a work order ahead of its due date.

Vessels and piping

External inspections with photos

Inspections on the calendar, with photos of what was found on the work order.

Instruments

Controls in their own group

Instrumentation and controls is one of SiteWise's equipment categories, so transmitters and controllers sit together.

Safety equipment

Weekly and monthly checks

Eyewash stations, safety showers and fire extinguishers, each with its own checklist on its own PM.

Parts

Seals and gaskets held ahead

Gaskets, seals and packing reserved 30 days ahead of a planned PM, counted per storeroom.

Records

Where a chemical plant needs inspection records

RuleWhat it asksHow SiteWise keeps it
OSHA process safety management, 29 CFR 1910.119(j)For covered processes: inspections and tests on process equipment, each one documentedA work order for each inspection, with the date it was due, the person it was assigned to and the checklist version it was done to
NFPA 10, portable fire extinguishersA visual inspection at intervals of no more than 31 daysA monthly PM on every extinguisher, with its checklist

SiteWise keeps the records. Your PSM program decides which equipment is covered and how often. Sources: OSHA process safety management, documenting each inspection and test, 29 CFR 1910.119(j)(4)(iv): OSHA interpretation letter, 16 September 1996; NFPA 10, portable fire extinguishers inspected at intervals of no more than 31 days (section 7.2.1.2): quoted in NFPA 302, Annex E.

IoT integration

IoT sensors on the pumps and the cold storage

EcoWise

Pumps, agitators and fans

EcoWise reads the current each motor draws, and how its load changes, on pumps, agitators, compressors and cooling tower fans. When a motor starts to struggle, it raises an alert.

About EcoWise

TemperatureWise

Cold storage

TemperatureWise watches walk-in coolers and freezers, such as cold storage for materials that must stay cold, and raises an alert when one drifts out of range.

About TemperatureWise

When either sensor raises an alert, it adds a work order request for approval, or a work order straight away, as you choose. Other systems, such as a PLC, connect on the Enterprise plan. How IoT alerts become work orders

A working day

Three scenes from a working day at a chemical plant

  1. 6:30, the day's inspections

    The day's inspections opened as work orders a week ago. The supervisor assigns them to the day shift from a computer.

  2. 10:15, a weeping seal

    A technician on the pump rack finds a seal weeping. Photos and a 30-second video go on a new work order, marked high priority.

  3. 14:00, the audit question

    An auditor asks for last quarter's relief valve tests. Filter the work orders by asset: each one shows the checklist version it was done to.

Set up for you

SiteWise keeps the work and the record; your PSM program sets the scope

SiteWise is not a process safety system. Your process safety management program decides which equipment is covered and how often it is inspected. SiteWise schedules the work, puts it on the phone and keeps the record.

SiteWise schedules PMs by the calendar: every so many days, weeks or months, or from when the last one was done. Create, update and close work orders and PMs offline, on every plan. Your data can be hosted in your region.

When you sign up, SiteWise asks for your industry and sets the app up for it, starting with the equipment categories your team will use.

Common questions

Can SiteWise keep PSM mechanical integrity records?

Yes, for the work. SiteWise schedules each inspection and test as a work order and keeps it with the checklist version it was done to. Your PSM program still decides which equipment is covered and how often.

Do old work orders change when we update a checklist?

No. Edit a template once and every PM that uses it takes the change. Work orders already issued keep the version they were issued with.

Can technicians use it where there is no signal?

Yes. Create, update and close work orders and PMs offline, on every plan.

Can each unit keep its own storeroom?

Yes. Each SiteWise storeroom has its own minimum and maximum per part, and crib attendants can be limited to their own storeroom.

Can contractors close their own work orders?

Yes. Outside vendors can receive and close work orders.

Put one unit on SiteWise today

Download the app free and set up one unit's inspections. Send us the rest, and we import them for you.

Moving off a spreadsheet? Send us your spreadsheet or export; we import it for you, free, usually in 2 to 4 business days. Email it to us

Download on the App StoreGet it on Google Play

Free on iPhone and Android.

Last reviewed 23 November 2026