SiteWise inspections and checklists
Inspection checklists kept in one place, with every version on record
SiteWise keeps checklist templates in one place for your whole organization and adds them to each PM. Edit a template once and every PM that uses it takes the change. Work orders already issued keep the version they were issued with. The technician works through the checklist on the phone, offline if need be, with photos and video on the work order.
Free on iPhone and Android.
An example template
Monthly fire extinguisher check
- In place and easy to reach
- Pressure gauge in the operating range
- Pin and tamper seal intact
- No damage, leaks or corrosion
- Tag dated
One template, added to the extinguisher PM at every site.
Edit a checklist once, and every PM uses the new version
Work orders already opened keep the version they started with, so the record shows what was checked.
Checklists live in the organization's procedure library, edited in one place.
The monthly extinguisher round, the forklift check or the generator run: each PM carries its checklist.
Each step is ticked on the work order, with a photo where it helps.
Change the template, and new work orders use the new version. Open and closed work orders keep theirs.
* An illustration of the steps only, with made-up data. Text in the real app is smaller.
How it works
One template reaches every PM, and every work order keeps its version
Write the template once
Build the checklist for your whole organization: an extinguisher check, a rooftop unit PM, a forklift's daily check.
Add it to each PM
A PM is in effect a work order template. Add the checklist, and every work order the PM opens carries it.
Edit it in one place
Change the template once and every PM that uses it takes the change, at every site.
Keep the version
Work orders already issued keep the checklist version they were issued with, so the record shows exactly what was checked.
Clipboard or SiteWise
A clipboard checklist and a SiteWise checklist keep different records
| The question | Clipboard checklist | SiteWise checklist |
|---|---|---|
| Is every site using the latest one? | Only if someone reprinted it | Every PM takes the edit |
| What did we check last March? | Find the right sheet in the binder | The work order kept the version it was done to |
| Was it done at all? | A missing sheet proves nothing | The PM opened the work order, and its status shows if it closed |
| What did the problem look like? | A note in the margin | Photos, and a video up to 30 seconds |
| No signal in the plant room | Fine, it is paper | Fine, it works offline too |
Where teams use it
Checks that recur on a schedule belong on a PM
Safety
Life safety checks
Fire extinguishers, eyewash stations, emergency lighting and generator runs, each on its own PM.
Equipment
The maker's steps
Rooftop units, boilers, compressors and conveyors, with the manufacturer's steps as a checklist.
Daily
Start-of-shift checks
A forklift's pre-shift check or a line's start-up check, as a daily PM.
Audits
What was checked, and when
Food safety, quality and insurance audits ask what was checked and when. Each work order answers with its own version.
Procedures
Steps with photos and video
Procedures with steps, photos and video can be attached to work orders and PMs as well.
Every site
One standard everywhere
The same template on the same PM at every site, so the job is done the same way.
On the record
A checklist in SiteWise sits with the machine it checks
SiteWise ties each checklist to a PM, and each PM to its equipment. The record of a check sits on the machine's history, next to its repairs, not in a separate forms app.
Have your checklists on paper? Send us your checklist: we set it up as a PM in your account, free.
Common questions
No. Edit a template once and every PM that uses it takes the change. Work orders already issued keep the version they were issued with.
Yes. SiteWise keeps templates in one place for your whole organization, and the same template can be added to PMs at every site.
Yes. Create, update and close work orders and PMs offline, on every plan.
Yes. Photos, and videos up to 30 seconds and 50 MB, go on the work order the checklist belongs to.
Yes. Send us your checklist: we set it up as a PM in your account, free.
SiteWise. Set the extinguisher round as a monthly PM with its checklist: NFPA 10 asks for an inspection at intervals of no more than 31 days (NFPA 10, 7.2.1.2). Sprinkler control valves get their own PMs, weekly, or monthly where a valve is locked or monitored, as NFPA 25 sets (NFPA 25, 13.3.2). A QR tag on each extinguisher or valve opens its checklist.
SiteWise, with one PM per truck that opens each day and a checklist for the pre-shift check. OSHA asks for forklifts to be examined at least daily before use (29 CFR 1910.178(q)(7)). A QR tag on the truck opens its checklist, and a problem found goes in as a request from the same phone.
SiteWise. NFPA 101 asks for a 30-second test of each emergency light every month and a 90-minute test once a year (NFPA 101, 7.9.3). Set both as PMs, each with its checklist, and the record shows who tested which light and when.
SiteWise. NFPA 110 asks for a standby generator to be inspected weekly and run under load at least monthly (NFPA 110, 8.4). Set the weekly inspection and the monthly run as two PMs, with the generator's name in both titles, since each PM has one frequency.
Put your first checklist on a PM today
Download the app free and add a checklist to one machine's PM.
Checklists on paper? Send us your checklist: we set it up as a PM in your account, free. Email it to us
Job by job
More on SiteWise
- SiteWisePreventive maintenancePMs by the calendar, parts held ahead
- SiteWisePredictive maintenanceSensor alerts that open work orders
- SiteWiseWork order appOffline, photos, QR scans and chat
- SiteWiseReportingDashboards in the app
- ManufacturingChemicalsInspections with a record for every test
- SiteWisePlans and pricingFree, Premium and Enterprise, line by line