SiteWise for manufacturing
Manufacturing maintenance software for every plant you run
SiteWise is manufacturing maintenance software: a CMMS for the team that keeps the presses, lines, pumps and compressors running. It schedules PMs, holds the parts for each one 30 days ahead, puts the steps and checklists on the technician's phone, and keeps every repair on record for your audits. Every plant sits in one account.
Free on iPhone and Android.
Manufacturing
What a plant maintenance team runs in SiteWise
- Presses and molding machines
- Pumps, fans and compressors
- Conveyors and packaging lines
- Chillers, dryers and cooling
- Spare parts and tools
- Safety and quality checks
Free plan: unlimited work orders, no limit on users. See the limits
By kind of plant
Manufacturing maintenance for the kind of plant you run
Five kinds of plant, each with its own page: the equipment, the records your audits ask for, and the sensors that watch the motors.
Chemicals
Chemical plants
Inspections and tests on pumps, valves, vessels and relief devices, each kept with the checklist version it was done to.
Chemical plant maintenance softwarePlastics
Plastics plants
PMs on injection molding machines, extruders, chillers and dryers, with each mold kept as an asset with its own history.
Plastics plant maintenance softwarePackaging
Packaging and corrugated plants
Case erectors, tapers, palletizers and stretch wrappers on schedule, with the machine maker's steps on the phone.
Packaging plant maintenance softwareFood manufacturing
Food and beverage plants
Mixers, fillers, ovens and freezers on their PMs, with every repair on record for your audits.
Food manufacturing maintenance softwareAutomotive
Automotive parts plants
Planned maintenance on presses, welders, robots and CNC machines, with critical spares held ahead.
Automotive plant maintenance softwareAny plant
Another kind of plant
SiteWise asks for your industry when you sign up and sets the app up for it, starting with the equipment categories your team will use.
What SiteWise doesThe equipment
What a plant maintenance team keeps on a schedule
Presses and molding machines
Every press on its own PMs
Press and die PMs, with the maker's procedure and lockout steps linked.
Pumps, fans and compressors
Motors watched between PMs
Renergy's EcoWise reads the current each motor draws, and raises an alert when one starts to struggle.
About EcoWiseConveyors and lines
Chains, belts and drives
Chains, rollers, drives and guards on schedule, with photos on every repair.
Chillers and cooling
Cooling kept on its PMs
Chillers, cooling towers and dryers on PMs, and cold rooms watched by Renergy's TemperatureWise.
About TemperatureWiseSpare parts
Parts held 30 days ahead
Seals, belts, blades and filters reserved for each PM before it is due, per storeroom.
Parts and inventorySafety and quality checks
One template, every version kept
Inspections on a checklist, with each work order kept with the version it was done to.
Inspections and checklistsRecords
The records your audits may ask for
| Rule | What it asks | How SiteWise keeps it |
|---|---|---|
| OSHA process safety management, 29 CFR 1910.119(j) | For covered processes: inspections and tests on process equipment, each one documented | A work order for each inspection, with the date it was due, the person it was assigned to and the checklist version it was done to |
| 21 CFR 117.40, food plant equipment | Plant equipment must be adequately maintained | A PM for every machine, and a work order for every repair, kept on the asset |
| IATF 16949, clause 8.5.1.5 | A documented maintenance system: the key process equipment, replacement parts for it, and planned maintenance with objectives | Each machine as an asset, PMs on schedule, spare parts per storeroom held ahead of PMs, and planned work filtered apart from breakdowns |
| NFPA 10, portable fire extinguishers | A visual inspection at intervals of no more than 31 days | A monthly PM on every extinguisher, with its checklist |
Which rules apply depends on your process, your customers and your local authority. SiteWise keeps the schedule and the record. More on each in chemical plants, food plants and automotive plants. Sources: OSHA process safety management, documenting each inspection and test, 29 CFR 1910.119(j)(4)(iv): OSHA interpretation letter, 16 September 1996; FDA current good manufacturing practice, equipment adequately maintained: 21 CFR 117.40; IATF 16949:2016 clause 8.5.1.5, total productive maintenance: BSI course outline; what the clause asks, as summarized on Advisera (the standard itself is sold by IATF); NFPA 10, portable fire extinguishers inspected at intervals of no more than 31 days (section 7.2.1.2): quoted in NFPA 302, Annex E.
Set up for you
Scheduled PMs, parts held ahead and every plant in one account
SiteWise schedules PMs every so many days, weeks or months, or from when the last one was done, and opens each work order before it is due. Renergy's EcoWise sensors also open a work order on their own when a motor's reading crosses its limit. For machines serviced by hours, cycles or shots, set each PM's interval from the typical use, and change it when the use changes.
The parts for each PM are reserved 30 days ahead, so the technician does not open the work order and find the seal is not on the shelf. Planned work filters apart from breakdowns, so you can see how much of the week went to each.
Technicians create, update and close work orders and PMs offline, on every plan, at the press or in a plant room with no signal.
Every plant is a location in one account. Filter work orders by location, or by team, to see each plant's open and overdue work. More in multi-site maintenance.
Common questions
Software that runs a plant's maintenance: the machines as assets, the PMs on them, the work orders and spare parts, and the history of every repair. SiteWise is a CMMS for this, on the phone and on the web.
Yes. Each plant is a location. The free plan covers 20 locations, and Premium has no limit.
Close to it. Set each PM's interval from the machine's typical weekly hours, cycles or shots, and change it when the use changes. Renergy's EcoWise sensors can also open a work order on their own when a motor's reading crosses its limit.
Yes, for the maintenance record. Every PM and repair is a work order on the asset, with who did it, when, and the checklist version it was done to. Which records an audit asks for is set by your standard, your customer or your regulator.
Yes. Technicians create, update and close work orders and PMs offline, on every plan.
SiteWise is free to start: unlimited work orders, 100 PMs (preventive maintenance schedules), 20 locations, 250 assets, 250 parts, 100 tools and 25 vendors, with no limit on users. Premium removes every limit for $15 per user per month, billed annually.
Put one line on SiteWise today
Download the app free and set up one line. Send us the rest of your equipment list, and we import it for you.
Moving off a spreadsheet? Send us your spreadsheet or export; we import it for you, free, usually in 2 to 4 business days. Email it to us
Related
SiteWise use cases for plant maintenance teams
- SiteWisePreventive maintenanceScheduled PMs, parts held ahead
- SiteWisePredictive maintenanceSensor alerts that open work orders
- SiteWiseParts and inventoryStorerooms, reserved parts and counts
- SiteWiseTool cribTools checked out to work orders
- SiteWiseInspections and checklistsOne template, every PM, every version kept
- SiteWiseMany sitesEvery site in one account