Ice machines

Ice machine water filters: what they do, which kind, and when to change them

By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 5 November 2026

This is a continuation of Commercial ice machine maintenance, a 5-part tutorial. You are on part 3 of 5.

An ice machine water filter does up to three jobs: it catches sediment, its carbon takes out chlorine taste and smell, and a scale inhibitor keeps minerals dissolved, so less scale forms on the plate. Change the cartridge on its date or its gallons, whichever comes first.

Six months is common. 3M rates its HF20-S cartridge for one year or 9,000 gallons, and Ice-O-Matic says to replace its IOMQ cartridges every six months.

A filter does three jobs, and most cartridges do all three

An animated drawing of water flowing from the supply line through an ice machine water filter to the machine. The first stage catches sediment, so grit stops there. The second stage is carbon, which takes out the chlorine taste and smell. The third stage is a scale inhibitor, which keeps the minerals dissolved so they pass through instead of sticking to the plate. Many cartridges do all three in one. Change the cartridge on its date or its gallons, whichever comes first.

A scale inhibitor slows scale, but it does not remove the minerals

The inhibitor does not take the minerals out of the water. It keeps them dissolved, so less of them coat the plate. The machine still needs its clean and sanitize on the maker's schedule, every six months for most, and more often on hard water: Scotsman says four times a year where the water is highly mineralized.

An animated drawing in four panels of an evaporator plate. First, a clean plate: the ice forms evenly and the batch is quick. Second, a thin crust of scale starts on the plate from minerals in the water, and the batch takes longer. Third, heavy scale: the cubes come out thin and uneven, some stick to the plate, and the batch is slow. Fourth, after cleaning: the acid cleaner dissolves the scale, and the plate is back to the first panel.

Soft, cloudy or slow ice often starts with the water

Manitowoc's manuals list poor incoming water and poor filtering among the first causes of soft or cloudy ice, with a dirty machine and a dirty screen at the water inlet. Their fix includes having a qualified company test the water and recommend a filter.

A clogged cartridge also cuts the water flow. That can slow the machine or stop it filling. Commercial ice machine repair has the other checks.

Change the cartridge on its date or its gallons, whichever comes first

Each cartridge is rated for a number of months and a number of gallons. A busy machine reaches the gallons first; a quiet one reaches the date first.

Cartridge lives as the makers rate them. Your cartridge's label comes first.
Cartridge
Rated for
Notes
3M HF20-S (for the ICE120-S system)
1 year or 9,000 gallons
Whichever comes first
Manitowoc Arctic Pure Plus AR-10000-P
15,000 gallons
0.5 micron, with a scale inhibitor
Ice-O-Matic IOMQ
Every 6 months
For the IFQ systems

Write the install date on the cartridge. It is the only way the next person knows how old it is.

Choose the filter by the machine's maker and its ice output

Then follow the label on the filter head for how to change the cartridge and flush it.

The filter change is a PM row of its own

The ice machine PM schedule, as a template. Your manual's figures come first.
Task
How often
Who
Notes
Clean and sanitize the water system
Every 6 months for most makers (Hoshizaki KM: at least yearly), or the manual's interval. More often with hard water
Trained staff or a service company
Use the cleaner and sanitizer the manual names. Never mix them
Wash the bin
At each clean
Trained staff
With the solution the manual gives
Throw away the first batches after a clean
At each clean
Trained staff
Ice-O-Matic says the first two batches after cleaning, and again after sanitizing
Change the water filter cartridge
On its date or its gallons, whichever comes first
Trained staff
Write the date on the cartridge
Check and clean the air-cooled condenser
At each clean, or as the manual says (some makers say monthly)
Trained staff, power off
Vacuum or soft brush
Check the condenser air filter, where fitted
Twice a month (Hoshizaki KM-255BAH)
Anyone
Rinse or replace as the manual says

SiteWise keeps the ice machine's PM on schedule and the history in one place

A cartridge looks the same on its last day as on its first, so the change gets skipped.

And the filter is one job on one machine. The same machine needs a clean, a sanitize, the bin washed and the condenser kept clear, each on its own interval. A kitchen or a site often has 10 to 15 machines like it, each with a list of its own. A paper checklist on the wall cannot keep that many dates, and it cannot tell anyone when one is missed.

SiteWise keeps all of it on your phone, in a free app. Yes, really free: the free plan has unlimited work orders (100 open at a time), 20 locations and 250 assets, far more than 15 machines.

SiteWise is a CMMS (a computerized maintenance management system): software that holds the assets, schedules the PMs, issues the work orders and keeps the history.

An animated drawing of SiteWise handling an ice machine fault. An ice machine at a made-up site, Bar 2, shows thin cubes and a fault code. On a phone, a SiteWise work order appears: 'Ice machine, Bar 2: thin cubes', priority high, assigned to the maintenance team, with a photo. Its status moves from open to in progress to complete. Beside it, a calendar shows the next preventive maintenance, clean and sanitize every 6 months, already scheduled.

Keep cartridges as parts in SiteWise with a minimum per storeroom; the consumption ledger projects what your planned PMs will use.

Download the PM schedule above as a spreadsheet: ice machine PM schedule (CSV). The plans are on the SiteWise page.

Common questions

How often should you change an ice machine water filter?

On the cartridge's date or its gallons, whichever comes first, and about every six months is common. 3M rates the HF20-S for one year or 9,000 gallons; Ice-O-Matic says every six months for its IOMQ cartridges.

A busy machine reaches its gallons sooner. Write the install date on the cartridge.

Does a commercial ice machine need a water filter?

Most do better with one. Poor incoming water and poor filtering are among the first causes Manitowoc lists for soft or cloudy ice, and a scale inhibitor slows the scale that makes batches slow.

Does an ice machine filter remove minerals?

No, not the scale inhibitor kind. It keeps the minerals dissolved so they pass through instead of sticking. The machine still needs cleaning on the maker's schedule.

Can you use reverse osmosis water in an ice machine?

Check with the maker first. Ice-O-Matic warns that RO water without a neutral pH can void its warranty.

Does a water filter mean you can clean the ice machine less often?

No. The maker's interval still applies, every six months for most, and hard water calls for more. Scotsman says four times a year where the water is highly mineralized.

Never miss a filter change