Ice machine maintenance by brand
By Vimal Bhaya, Founder and Lead Systems Architect · Last reviewed 5 November 2026
Manitowoc, Scotsman, Hoshizaki and Ice-O-Matic each clean, alarm and filter a little differently. Each page gives one maker's clean cycle, the cleaner it names, the codes it shows and where its manuals are.
The biggest difference is the evaporator: Hoshizaki says its stainless cubers take any commercial ice machine cleaner, while Ice-O-Matic requires a nickel-safe one. Some models need a specific cleaner, so check your manual either way.
The 4 parts, in order
Go straight to your maker's page, or read all four if you run more than one brand.
-
1. Manitowoc ice machine maintenance: cleaning, codes, filters and parts
The Indigo NXT clean cycle, Manitowoc's own cleaner, what safety limits 1 and 2 mean, and Arctic Pure filters.
Read part 1 -
2. Scotsman ice machine maintenance and repair
Not making ice: the checks. What F, H, B and the number codes mean. The Clear 1 clean, and the filters.
Read part 2 -
3. Hoshizaki ice machine maintenance: cleaning, beep codes and the manual
Hoshizaki's stainless evaporator takes any commercial cleaner. The KM clean, and what one, two and three beeps mean.
Read part 3 -
4. Ice-O-Matic ice machine maintenance and repair
Nickel-safe cleaner and sanitizer, every six months but no more than monthly. Error code 7, and the reset.
Read part 4
How to use this
Read them in order if you are starting from scratch. That is the usual path. If you already know which piece you need, jump to it from the list above.
The four makers, side by side
Maker | Cleaner | How often | Codes | Filters |
|---|---|---|---|---|
Manitowoc | Manitowoc's own; never mixed with the sanitizer | Every 6 months | Safety limit 1 (long freeze), 2 (long harvest) | Arctic Pure |
Scotsman | Clear 1, safe on nickel plating; no bleach | About twice a year; 4 times on hard water | 1 long freeze, 2 long harvest; F, H, B and more | AquaPatrol |
Hoshizaki | Any commercial cleaner; Scale Away, Lime-A-Way | At least once a year (KM cubers) | 1, 2 or 3 beeps | Its own and others |
Ice-O-Matic | Nickel-safe cleaner and sanitizer | Every 6 months, not more than monthly | Code 7 (water) on Elevation | IFQ |